TB-4015 Page 4 of 5
3. Replace the main filter. Ensure the main filter is placed inside the alignment pins so that the
interlock switch is depressed.
4. Replace the filter cover and ensure a proper fit to the bottom housing. Hook both latches into
the filter cover and press down carefully to engage each latch to the base.
5. Reconnect power cord and turn system on.
6. If the unit does not operate, refer to the troubleshooting section.
Caution
To prevent overheating, units should not be operated with a blocked filter condition, or with dust
obstruction of inlets or outlets.
Model 35470
Filter replacement indication
As fumes are filtered inside the unit, any particulate will be captured and over time will start
to clog the filter. This clogging will result in a reduction of the airflow, which may reduce the
amount of fumes extracted from the work area. Once the filter starts to become blocked an
audible alarm will sound from the main unit. This is to signify that filter replacement is required.
35472, 35473 - HEPA/GAS Filters Only
As fumes are filtered inside the unit, any particulate will be captured and over time will start to
clog the filter. The coarse particles are collected in the pre-filter while fine particulate will be
collected in the HEPA filter. This clogging will result in a reduction of the airflow, which may
reduce the amount of fumes extracted from the work area. Once the filters starts to become
blocked an audible alarm will sound from the main unit. This is to signify that filter replacement.
When using a HEPA or Gas Filter initially replace the pre-filter (35471). If this does not silence
the alarm then replace the main filter too.
Pre-filters should be replaced approximately every 4 – 6 weeks depending on the application.
We recommend that a stock of replacement filters be kept for optimal extraction performance
and minimum down-time. MENDA part number 35471.
Warning! Do not attempt to clean filters. Attempted cleaning can damage filters and cause
potential risk to health and equipment.
Note: MENDA recommends replacement of Main Filters annually as a minimum. Use only
original replacement filters.
Problem
Possible Cause
Check
No air flow
No Power
Check On/Off switch
Check power outlet
Check power cord
Check safety interlock switch
Poor
Air Leak
Check hose/arm for leaks
Performance
Check hose/arm for proper installation
Check hose/arm for partial clogging



Html Pages

1 2 3 4 5


Datenblatt Download

Go To PDF Page


Link URL



War ALLDATASHEET hilfreich?  [ DONATE ] 

Über Alldatasheet   |   Werbung   |   Kontakt   |   Privatsphäre und Datenschutz   |   Link zum Datenblatt    |   Linktausch   |   Hersteller
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com