  A6285 Datasheet HTML 1Page - Allegro MicroSystems A6285 Datasheet HTML 2Page - Allegro MicroSystems A6285 Datasheet HTML 3Page - Allegro MicroSystems A6285 Datasheet HTML 4Page - Allegro MicroSystems A6285 Datasheet HTML 5Page - Allegro MicroSystems A6285 Datasheet HTML 6Page - Allegro MicroSystems A6285 Datasheet HTML 7Page - Allegro MicroSystems A6285 Datasheet HTML 8Page - Allegro MicroSystems A6285 Datasheet HTML 9Page - Allegro MicroSystems Next Button
Zoom Inzoom in Zoom Outzoom out
 4 / 13 page
background image
16-Channel Constant-Current Latched LED Driver
with Open LED Detection and Dot Correction
A6285
4
Allegro MicroSystems, Inc.
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com
24
23
22
21
20
19
18
17
1
2
3
4
5
6
7
8
SDO
PE
OUT15
OUT14
PGND
OUT13
OUT12
OUT11
PAD
SDI
NC
OUT0
OUT1
PGND
OUT2
OUT3
OUT4
Terminal List Table
Name
Number
Description
O¯¯E¯
30
Output Enable input. Active low. When O¯¯E¯ = High, all OUTx outputs are forced OFF. When O¯¯E¯ = Low,
ON/OFF of OUTx outputs are controlled by input data.
GND
29
Logic supply ground.
PE
23
Active Pull-up Enable. When connected to LED Load Supply (VLED) = enabled, when connected to PGND
= disabled.
REXT
27
Reference current input/output terminal.
MODE
26
Logic input, Mode select. When MODE = Low, then SDI, SDO, CLK, LE are connected to ON/OFF control
logic. When MODE = High, SDI, SDO, CLK, LE are connected to dot-correction logic.
NC
2
No connection. Not internally connected.
OUT0
3
Constant current outputs.
OUT1
4
OUT2
6
OUT3
7
OUT4
8
OUT5
9
OUT6
11
OUT7
12
OUT8
13
OUT9
14
OUT10
16
OUT11
17
OUT12
18
OUT13
19
OUT14
21
OUT15
22
PGND
5, 10, 15, 20
Power ground.
CLK
32
Data shift clock input. Note that the internal connections are switched by input at MODE pin. At CLK↑, the
shift-registers selected by MODE shift the data.
SDI
1
Serial Data In. Data input of serial data interface.
SDO
24
Serial Data Out. Data output of serial data interface.
VDD
28
Logic Supply.
FAULT
25
Error output. FAULT is open drain terminal. FAULT goes low when LOD or TSD detected.
LE
31
Latch Enable input. Note that the internal connections are switched by input at the MODE pin. At LE↑, the
latches selected by MODE get new data.
PAD
Exposed pad for enhanced thermal dissipation; not connected internally, connect to power ground plane.
Pin-out Diagram



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13


Datenblatt Download

Go To PDF Page


Link URL



War ALLDATASHEET hilfreich?  [ DONATE ] 

Über Alldatasheet   |   Werbung   |   Kontakt   |   Privatsphäre und Datenschutz   |   Link zum Datenblatt    |   Linktausch   |   Hersteller
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com