| Datenblatt-Suchmaschine für elektronische Bauteile |
|
E54-CT1.. Datenblatt(PDF) 4 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E54-CT1.. Datenblatt(HTML) 4 Page - Omron Electronics LLC |
|
4 / 7 page ![]() E5AN E5AN 50 Specifications Table – continued from previous page EMC Emission Enclosure: EN55011 Group 1 class A Emission AC Mains: EN55011 Group 1 class A Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2) 8 kV air discharge (level 3) Immunity RF-interference: ENV50140: 10 V/m (amplitude modulated, 80 MHz to 1 GHz) (level 3) 10 V/m (pulse modulated, 900 MHz) Immunity Conducted Disturbance: ENV50141: 10 V (0.15 to 80 MHz) (level 3) Immunity Burst: EN61000-4-4: 2 kV power-line (level 3) 2 kV I/O signal-line (level 4) Approved standards UL3121-1, CSA22.2 No. 14, E.B.1402C Conforms to EN50081-2, EN50082-2, EN61010-1 (IEC61010-1) Conforms to VDE0106/part 100 (Finger Protection) when the terminal cover is mounted. J COMMUNICATIONS SPECIFICATIONS Transmission path connection Multiple points Communications method (See Note 1) RS-485 (two-wire, half duplex)/RS-232C Synchronization method Start-stop synchronization Baud rate 1,200/2,400/4,800/9,600/19,200 bps Transmission code ASCII Data bit length (See Note 2) 7 or 8 bits Stop bit length (See Note 2) 1 or 2 bits Error detection Vertical parity (none, even, odd) Frame check sequence (FCS): with SYSMAC WAY Block check character (BCC): with CompoWay/F Flow control Not available Interface (See Note 1) RS-485/RS-232C Retry function Not available Communications buffer 40 bytes Note: 1. RS-232C communications are only supported for the E5AN and E5EN models. 2. The baud rate, data bit length, stop bit length, or vertical parity can be individually set using the communications setting level. J CURRENT TRANSFORMER RATINGS Part number E54-CT1 E54-CT3 Max. continuous heater current 50 amps 120 amps Dielectric strength 1,000 VAC (for 1 min) Vibration resistance 50 Hz, 98 m/s2 (10G) Weight Approx. 11.5 g Approx. 50 g Accessories –– Armature: 2; Plug: 2 J HEATER BURNOUT ALARM Max. heater current Single-phase 50 A VAC (See Note 1.) Heater current value display accuracy ±5% FS±1 digit max. Heater burnout alarm setting range 0.1 to 49.9 A (in units of 0.1 A) (See Note 2.) Min. detection ON time 190 ms (See Note 3.) Note: 1. Use the K2CU-F jjA-jGS (with gate input terminals) for the detection of three-phase heater burnout. 2. The heater burnout alarm is always OFF if the alarm is set to 0.0 A and always ON if the alarm is set to 50.0 A. 3. No heater burnout detection or heater current value measurement is possible if the control output (heat) is ON for less than 190 ms. |
|
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |