12 / 16 page ![]() AD8207 Rev. 0 | Page 12 of 16 OUTPUT OFFSET ADJUSTMENT The output of the AD8207 can be adjusted for unidirectional or bidirectional operation. UNIDIRECTIONAL OPERATION Unidirectional operation allows the AD8207 to measure currents through a resistive shunt in one direction. The basic modes for unidirectional operation are ground referenced output mode and V+ referenced output mode. For unidirectional operation, the output can be set at the negative rail (near ground) or at the positive rail (near V+) when the differential input is 0 V. The output moves to the opposite rail when a correct polarity differential input voltage is applied. In this case, full scale is approximately 250 mV for a 5 V supply or 165 mV for a 3.3 V supply. The required polarity of the differential input depends on the output voltage setting. If the output is set at the positive rail, the input polarity must be negative to move the output down. If the output is set at ground, the polarity must be positive to move the output up. Ground Referenced Output Mode When using the AD8207 in the ground referenced output mode, both reference inputs are tied to ground, which causes the output to sit at the negative rail when there are 0 differential volts at the input (see Figure 28). REF ZERO DRIFT +IN –IN OUT V+ GND VREF1 VREF2 RANGE AD8207 5V Figure 28. Ground Referenced Output Mode, V+ = 5 V Table 4. Ground Referenced Output VIN (Referred to −IN) VO V+ = 5 V 0 V 0.02 V 250 mV 4.95 V V+ = 3.3 V 0 V 0.02 V 165 mV 3.25 V V+ Referenced Output Mode The V+ referenced output mode is set when both reference pins are tied to the positive supply. This mode is typically used when the diagnostic scheme requires detection of the amplifier and the wiring before power is applied to the load (see Figure 29). RANGE REF ZERO DRIFT +IN –IN OUT V+ GND VREF1 VREF2 AD8207 5V Figure 29. V+ Referenced Output Mode, V+ = 5 V Table 5. V+ Referenced Output VIN (Referred to −IN) VO V+ = 5 V 0 V 4.95 V −250 mV 0.02 V V+ = 3.3 V 0 V 3.25 V −165 mV 0.02 V BIDIRECTIONAL OPERATION Bidirectional operation allows the AD8207 to measure currents through a resistive shunt in two directions. In this case, the output is set anywhere within the output range. Typically, it is set at half scale for equal range in both directions. In some cases, however, it is set at a voltage other than half scale when the bidirectional current is asymmetrical. Table 6. VO = (V+/2) with VIN = 0 V VIN (Referred to −IN) VO V+ = 5 V +100 mV 4.5 V −100 mV 0.5 V V+ = 3.3 V +67.5 mV 3 V −67.5 mV 0.3 V Adjusting the output is accomplished by applying voltages to the reference inputs. VREF1 and VREF2 are tied to internal resistors that connect to an internal offset node. There is no operational difference between the pins. |
|
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |