6 / 12 page ![]() ATS137 SINGLE HALL EFFECT SWITCH ATS137 Rev. 10 6 of 12 FEBRUARY 2010 DS31045 www.diodes.com © Diodes Incorporated Application Information Operating principle: ATS137 is a three-pin Hall Effect switch IC which can turn magnetic flux variety to digital output signal. In other words, it is an interface from magnetic system to an electrical one by Hall effect. The illustrations are shown in Fig.1. VO Vce(SAT) VCC Magnetic Flux (Gauss) Turn On Turn Off hys B op B rp B Magnet Electrical S Marking Side Fig.1 Hall-Effect Switch Output driver is open-collector topology and maximum sink current (Isink) is 25mA. The illustrated circuit is shown as Fig. 2. ATS137 3.5 V ~20V Digital Output VCC DO GND Vo L R sink I Fig.2 Application Circuit |
|
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|