| Datenblatt-Suchmaschine für elektronische Bauteile |
|
CP2000AC54PE Datenblatt(PDF) 5 Page - Lineage Power Corporation |
|
|
|||||||||||||||||||||||||||||
CP2000AC54PE Datenblatt(HTML) 5 Page - Lineage Power Corporation |
|
5 / 8 page ![]() Data Sheet Compact Power Line CP2000AC54 Front-End Power Supply Lineage Power 5 Status and Control The rectifier provides three means for monitor/control: analog, PMBus compliant I 2C, or RS485 for interfacing to Lineage Power controllers or battery plants. Details of analog controls are provided in this data sheet under Signal Definitions. Lineage Power will provide separate application notes on PMBus protocol for users to interface to the CPL rectifiers. Contact your local Lineage Power representative for details. Hot Plug When rapidly extracting and reinserting modules care should be taken to allow for discharging the internal bias supply so that a predictable restart could be achieved. The way to ensure that the circuit sufficiently discharges is to observe the spinning of the fans after an extraction. The unit should not be reinserted until the fans stop spinning. Control Definitions All signals are referenced to Logic GRD unless otherwise noted. See the Signal Definitions Table at the end of this document for further description of all the signals. Input Signals Margining: Setpoint of the rectifier can be changed via this input pin. Programming can be either a voltage source or a resistance divider. The margining pin is connected to 3.3Vdc via a 10kΩ resistor inside the rectifier. See graphs below. An open circuit on this pin reverts the voltage level back to the original setting. Module Present Signal: This signal has dual functionality. It can be used to alert the system when a module is inserted. Has a 500 Ω resistor in series between this signal and Logic GRD. An external pull-up should not raise the voltage on the pin above 0.25Vdc. If raised the pin is raised to 5Vdc the write_protect feature of the EEPROM is enabled. Protocol Select: Establishes the communications mode of the power supply, between analog/I 2C and RS485 modes. For RS485, connect 750 – 3.92kΩ pull-down resistor to 54_OUT(-DC). Enable: On/Off control when either PMBus communications or analog functions are utilized as configured by the Protocol pin. This pin must be pulled low to turn ON the main output of the power supply. The power supply will turn OFF if either the Enable or the ON/OFF pin is released. The Enable function does not work with the RS-485 protocol. This signal is referenced to Logic_GRD. ON/OFF: This is a short pin utilized for hot-plug applications to ensure that the power supply turns OFF before the power pins are disengaged. It also ensures that the power supply turns ON only after the power pins have been engaged. Must be connected to 54_OUT (-DC). Output Signals Alert #: PMBus interrupt signal. Fault: This signal goes LO for any failure that requires rectifier replacement. Some of these faults may be due to: • Fan failure • Over-temperature condition • Over-temperature shutdown • Over-voltage shutdown • Internal Rectifier Fault Power Capacity: A HI on this pin indicates rectifier configured for 2000W operation; a LO indicates rectifier configured for 1200W operation. |
|
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |