19 / 25 page ![]() KP236 Analog Absolute Pressure Sensor Specification Data Sheet 19 Revision 1.0, 2010-06-21 3.3 Operating Range The following operating conditions must not be exceeded in order to ensure correct operation of the device. All parameters specified in the following sections refer to these operating conditions, unless noted otherwise. Table 7 Operating Range Parameter Symbol Values Unit Note / Test Condition Number Min. Typ. Max. Supply voltage V DD 4.5 5.0 5.5 V V OUT is ratiometric to V DD 2.1 Output current on V OUT pin I OUT – -1 – – 1 – mA mA pull-down resistor used pull-up resistor used 2.2 Operating temperature T a -40 – 125 °C 2.3 Ambient operating pressure range p amb 40 – 115 kPa 2.4 Lifetime 1) 1) The life time shall be considered as anticipation with regard to the product that shall not extend the agreed warranty period. t live 15 – – years 2.5 |
|
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|