  LV5216CS Datasheet HTML 1Page - Sanyo Semicon Device LV5216CS Datasheet HTML 2Page - Sanyo Semicon Device LV5216CS Datasheet HTML 3Page - Sanyo Semicon Device LV5216CS Datasheet HTML 4Page - Sanyo Semicon Device LV5216CS Datasheet HTML 5Page - Sanyo Semicon Device LV5216CS Datasheet HTML 6Page - Sanyo Semicon Device LV5216CS Datasheet HTML 7Page - Sanyo Semicon Device LV5216CS Datasheet HTML 8Page - Sanyo Semicon Device  
Zoom Inzoom in Zoom Outzoom out
 5 / 8 page
background image
LV5216CS
No.A1968-5/8
Serial Bus Communication Specifications
1) I
2C serial transfer timing conditions
Standard mode
Parameter
Symbol
Conditions
Min.
Typ.
Max.
Unit
SCL clock frequency
fsc1
SCL clock frequency
0
-
100
kHz
Data setup time
ts1
SCL setup time relative to the fall of SDA
4.7
-
-
μs
ts2
SDA setup time relative to the rise of SCL
250
-
-
ns
ts3
SCL setup time relative to the rise of SDA
4.0
-
-
μs
Data hold time
th1
SCL hold time relative to the fall of SDA
4.0
-
-
μs
th2
SDA hold time relative to the fall of SCL
0
-
-
μs
Pulse width
twL
SCL pulse width for the L period
4.7
-
-
μs
twH
SCL pulse width for the H period
4.0
-
-
μs
Input waveform
conditions
ton
SCL and SDA (input) rise time
-
-
1000
ns
tof
SCL and SDA (input) fall time
-
-
300
ns
Bus free time
tbuf
Time between STOP condition and START
condition
4.7
-
-
μs
High-speed mode
Parameter
Symbol
Conditions
Min.
Typ.
Max.
Unit
SCL clock frequency
fsc1
SCL clock frequency
0
-
400
kHz
Data setup time
ts1
SCL setup time relative to the fall of SDA
0.6
-
-
μs
ts2
SDA setup time relative to the rise of SCL
100
-
-
ns
ts3
SCL setup time relative to the rise of SDA
0.6
-
-
μs
Data hold time
th1
SCL hold time relative to the fall of SDA
0.6
-
-
μs
th2
SDA hold time relative to the fall of SCL
0
-
-
μs
Pulse width
twL
SCL pulse width for the L period
1.3
-
-
μs
twH
SCL pulse width for the H period
0.6
-
-
μs
Input waveform
conditions
ton
SCL and SDA (input) rise time
-
-
300
ns
tof
SCL and SDA (input) fall time
-
-
300
ns
Bus free time
tbuf
Time between STOP and START conditions
1.3
-
-
μs
th1
ts2
twL
th2
twH
th1
ts1
ts3
tbuf
SCL
SDA
ton
tof
START condition
STOP condition
Input waveform condition
Resend start condition



Html Pages

1 2 3 4 5 6 7 8


Datenblatt Download

Go To PDF Page


Link URL



War ALLDATASHEET hilfreich?  [ DONATE ] 

Über Alldatasheet   |   Werbung   |   Kontakt   |   Privatsphäre und Datenschutz   |   Link zum Datenblatt    |   Linktausch   |   Hersteller
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com