  HDLA-1414 Datasheet HTML 1Page - AVAGO TECHNOLOGIES LIMITED HDLA-1414 Datasheet HTML 2Page - AVAGO TECHNOLOGIES LIMITED HDLA-1414 Datasheet HTML 3Page - AVAGO TECHNOLOGIES LIMITED HDLA-1414 Datasheet HTML 4Page - AVAGO TECHNOLOGIES LIMITED HDLA-1414 Datasheet HTML 5Page - AVAGO TECHNOLOGIES LIMITED HDLA-1414 Datasheet HTML 6Page - AVAGO TECHNOLOGIES LIMITED HDLA-1414 Datasheet HTML 7Page - AVAGO TECHNOLOGIES LIMITED HDLA-1414 Datasheet HTML 8Page - AVAGO TECHNOLOGIES LIMITED HDLA-1414 Datasheet HTML 9Page - AVAGO TECHNOLOGIES LIMITED  
Zoom Inzoom in Zoom Outzoom out
 5 / 9 page
background image
5
High Efficiency Red HDLO-1414
Parameter
Symbol
Min.
Typ.
Units
Test Conditions
Average Luminous Intensity per Digit,
IV
1.2
3.5
mcd
“*” illuminated in All Four Digits.
Character Average
19 Dots ON per Digit.
Peak Wavelength
PEAK
635
nm
Dominant Wavelength[2]
D
626
nm
Orange HDLA-1414
Parameter
Symbol
Min.
Typ.
Units
Test Conditions
Average Luminous Intensity per Digit,
IV
1.2
3.5
mcd
“*” Illuminated in All Four Digits.
Character Average
19 Dots ON per Digit.
Peak Wavelength
PEAK
600
nm
Dominant Wavelength[2]
D
602
nm
Yellow HDLY-1414
Parameter
Symbol
Min.
Typ.
Units
Test Conditions
Average Luminous Intensity per Digit,
IV
1.2
3.7
mcd
“*” Illuminated in All Four Digits.
Character Average
19 Dots ON per Digit.
Peak Wavelength
PEAK
583
nm
Dominant Wavelength[2]
D
585
nm
Green HDLG-1414
Parameter
Symbol
Min.
Typ.
Units
Test Conditions
Average Luminous Intensity per Digit,
IV
1.2
5.6
mcd
“*” Illuminated in All Four Digits.
Character Average
19 Dots ON per Digit.
Peak Wavelength
PEAK
568
nm
Dominant Wavelength[2]
D
574
nm
Notes:
1. Refers to the initial case temperature of the device immediately prior to the light measurement.
2. Dominant wavelength,
D, is derived from the CIE chromaticity diagram, and represents the single wavelength which defines the color of the
device.



Html Pages

1 2 3 4 5 6 7 8 9


Datenblatt Download

Go To PDF Page


Link URL



War ALLDATASHEET hilfreich?  [ DONATE ] 

Über Alldatasheet   |   Werbung   |   Kontakt   |   Privatsphäre und Datenschutz   |   Link zum Datenblatt    |   Linktausch   |   Hersteller
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com