Datenblatt-Suchmaschine für elektronische Bauteile
  German  ▼
ALLDATASHEETDE.COM

X  

HCS500T-I/P Datenblatt(PDF) 24 Page - Microchip Technology

Teilenummer HCS500T-I/P
Bauteilbeschribung  KEELOQ Code Hopping Decoder
PDF  34 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Hersteller  MICROCHIP [Microchip Technology]
Direct Link  http://www.microchip.com
Logo MICROCHIP - Microchip Technology

HCS500T-I/P Datenblatt(HTML) 24 Page - Microchip Technology

Back Button HCS500T-I/P Datasheet HTML 20Page - Microchip Technology HCS500T-I/P Datasheet HTML 21Page - Microchip Technology HCS500T-I/P Datasheet HTML 22Page - Microchip Technology HCS500T-I/P Datasheet HTML 23Page - Microchip Technology HCS500T-I/P Datasheet HTML 24Page - Microchip Technology HCS500T-I/P Datasheet HTML 25Page - Microchip Technology HCS500T-I/P Datasheet HTML 26Page - Microchip Technology HCS500T-I/P Datasheet HTML 27Page - Microchip Technology HCS500T-I/P Datasheet HTML 28Page - Microchip Technology Next Button
Zoom Inzoom in Zoom Outzoom out
 24 / 34 page
background image
HCS500
DS40153C-page 24
© 2002 Microchip Technology Inc.
8.1.7
ERASE ALL COMMAND
8.1.8
PROGRAMMING COMMAND
Standard Operating Conditions (unless otherwise specified):
Commercial (C):
0°C
≤ TA ≤ +70°C
Industrial (I):
-40°C
≤ TA ≤ +85°C
Symbol
Parameters
Min
Typ
Max
Units
TERA
Learn command activation time
20
1000
µs
TACK
Decoder acknowledge time
20
210
ms
TRESP
Microcontroller acknowledge
response time
20
1000
µs
TACK2
Decoder data line low
10
µs
*
These parameters are characterized but not tested.
Standard Operating Conditions (unless otherwise specified):
Commercial (C):
0°C
≤ TA ≤ +70°C
Industrial (I):
-40°C
≤ TA ≤ +85°C
Symbol
Parameters
Min
Typ
Max
Units
TPP1
Command request time
500
ms
TPP2
Decoder acknowledge time
1
ms
TPP3
Start Command mode to first
command bit
20
1000
µs
TPP4
Data line low before tri-stated
5
µs
TCLKH
Clock high time
20
1000
µs
TCLKL
Clock low time
20
1000
µs
FCLK
Clock frequency
500
25000
Hz
TDS
Data hold time
5
µs
TCMD
Command validate time
10
µs
TACK
Command acknowledge time
30
240
ms
TWT2
Acknowledge respond time
20
1000
µs
TALW
Data low after clock low
10
µs
*
These parameters are characterized but not tested.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34


Datenblatt Download

Go To PDF Page


Link URL



War ALLDATASHEET hilfreich?  [ DONATE ] 

Über Alldatasheet   |   Werbung   |   Kontakt   |   Privatsphäre und Datenschutz   |   Link zum Datenblatt    |   Linktausch   |   Hersteller
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com