12 / 38 page ![]() MCP7940M DS22292A-page 12 Preliminary 2012 Microchip Technology Inc. • ALMxC2:0: These Configuration bits determine the alarm match. The logic will trigger the alarm based on one of the following match conditions: • The 12/24-hour bits 0xCh.6 and 0x13h.6 are cop- ies of the bit in 0x02h.6. The bits are read-only. 4.2 FEATURES 4.2.1 CALIBRATION The MCP7940M utilizes digital calibration to correct for inaccuracies of the input clock source (either external or crystal). Calibration is enabled by setting the value of the Calibration register at address 08H. Calibration is achieved by adding or subtracting a number of input clock cycles per minute in order to achieve ppm level adjustments in the internal timing function of the MCP7940M. The MSB of the Calibration register is the sign bit, with a ‘1’ indicating subtraction and a ‘0’ indicating addition. The remaining seven bits in the register indicate the number of input clock cycles (multiplied by two) that are subtracted or added per minute to the internal timing function. The internal timing function can be monitored using the MFP open-drain output pin by setting bit<6> (SQWE) and bits<2:0> (RS2, RS1, RS0) of the control register at address 07H. With the SQWE bit set to ‘1’, there are two methods that can be used to observe the internal timing function of the MCP7940M: A. RS2 BIT SET TO ‘0’ With the RS2 bit set to ‘0’, the RS1 and RS0 bits enable the following internal timing signals to be output on the MFP pin: The frequencies listed in the table presume an input clock source of exactly 32.768 kHz. In terms of the equivalent number of input clock cycles, the table becomes: With regards to the calibration function, the Calibration register setting has no impact upon the MFP output clock signal when bits RS1 and RS0 are set to ‘11’. The setting of the Calibration register to a non-zero value (i.e., values other than 00H or 80H) enables the calibration function which can be observed on the MFP output pin. The calibration function can be expressed in terms of the number of input clock cycles added/subtracted from the internal timing function. 000 – Seconds match 001 – Minutes match 010 – Hours match (takes into account 12/24 hour) 011 – Matches the current day, interrupt at 12.00.00 a.m. Example: 12 midnight on 100 –Date 101 – RESERVED 110 – RESERVED 111 – Seconds, Minutes, Hour, Day, Date, Month RS2 RS1 RS0 Output Signal 00 0 1 Hz 00 1 4.096 kHz 01 0 8.192 kHz 01 1 32.768 kHz RS2 RS1 RS0 Output Signal 00 0 32768 00 1 8 01 0 4 01 1 1 |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |