| Datenblatt-Suchmaschine für elektronische Bauteile |
|
AD652KP Datenblatt(PDF) 24 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD652KP Datenblatt(HTML) 24 Page - Analog Devices |
|
24 / 28 page ![]() AD652 Rev. C | Page 24 of 28 BRIDGE TRANSDUCER INTERFACE The circuit of Figure 38 illustrates a simple interface between the AD652 and a bridge-type transducer. The AD652 is an ideal choice because its buffered 5 V reference can be used as the bridge excitation, thereby ratiometrically eliminating the gain drift related errors. This reference provides a minimum of 10 mA of external current, which is adequate for bridge resistance of 600 Ω and above. If, for example, the bridge resistance is 120 Ω or 350 Ω, an external pull-up resistor (RPU) is required. RPU and can be calculated using the following formula: mA 10 V 5 V 5 (max) − − + = BRIDGE S PU R V R An instrumentation amplifier is used to condition the bridge signal before presenting it to the SVFC. With its high CMRR, the AD652 minimizes common-mode errors and can be set to arbitrary gains between 1 and 10,000 via three resistors, simplifying the scaling for the part’s calibrated 10 V input range. These resistors should be selected such that the following equation holds: ⎟⎟ ⎠ ⎞ ⎜⎜ ⎝ ⎛ + = 1 2 V 10 G F BRIDGE R R V where 10 kΩ ≤ RF ≤ 20 kΩ, and VBRIDGE is the maximum output voltage of the bridge. The bridge output may be unipolar, as is the case for most pressure transducers, or it may be bipolar as in some strain measurements. If the signal is unipolar, the reference input of the AD625 (Pin 7) is simply grounded. If the bridge has a bipolar output, however, the AD652 reference can be tied to Pin 7, thereby, converting a 5 V signal (after gain) into a 0 V to +10 V input for the SVFC. 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 ONE SHOT AND "D" FLOP QCK D Q 1mA 20k Ω AD652 SYNCHRONOUS VOLTAGE-TO- FREQUENCY CONVERTER 5V REFERENCE 9 8 11 7 10 1 5 2 15 12 16 AD625 RBRIDGE VBRIDGE + – RF RG RF +15V –15V 1 2 S1 +15V CLOCK IN FREQ OUT +15V VLOGIC RL RPU –15V CINT NOTES 1. RF SHOULD BE BETWEEN 10kΩ AND 20kΩ. 2. RPU NEEDED IF RBRIDGE 600Ω 3. S1 IN POSITION 1 FOR UNIPOLAR SIGNALS AND POSITION 2 FOR BIPOLAR SIGNALS. FOUT =VBRIDGE FCLOCK2 10V + 1 2RF RG Figure 38. Bridge Transducer Interface |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |