14 / 25 page ![]() www.austriamicrosystems.com/AS8002 Revision 1.1 13 - 24 AS8002 Data Sheet - D e t a i l e d D e s c r i p t i o n 7.6 Measurement Example The following example shows a simple way to alternately read the voltage and current values: Bits [b2:b0] in Addr 03h control the ADC input multiplexer: 1. Select the Current channel input (IOM, IOP) : 0610h - Set the Address [A6:A0] to 03h, - Set the R/W bit to 0 (write mode) and the data to 10h (adc_en = 1, mux_sel = 0) - In parallel to writing the 16-bit data on SDI, a set of 16-bit data can be read on SDO, which contains the data from the second to last command. 2. Select the Voltage channel input (V1M, V1P) : 0611h - Set the Address [A6:A0] to 03h, - Set the R/W bit to 0 (write mode) and the data to 11h (adc_en = 1, mux_sel = 1) - In parallel to writing the 16-bit data on SDI, a set of 16-bit data can be read on SDO, which contains the data from the second to last command. 3. Change the input multiplexer back to Current channel input (IOM, IOP) : 0610h - Repeat the sequence 1 above: addr = 03h, data = 10h, - The 16-bit current input data from the second to last invoked command (1 above) can be read on SDO. 4. Loop sequences 2 and 3 Note: In sequence 2, the 16-bit voltage input data from the second to last command can be read on SDO. Figure 8. Measurement Diagram Note: The 16-bit input data from the voltage and current measurements contain the ADC data in the lower 12 bits and two status bits in the upper 4 bits (see Register Map Table on page 15). Name Addr Default Content b7 b6 b5 b4 b3 b2 b1 b0 Input Multiplexer 03h 00h adc_en mux_sel[2:0] 0: Current channel PGA output 1: Voltage channel PGA output set Mux to Current measurement set Mux to Voltage measurement set Mux to Current measurement set Mux to Voltage measurement SDI MSB 0610h LSB data from previous command data from previous command read Current input value read Voltage input value SDO MSB LSB MSB LSB MSB LSB MSB LSB Transmission 1 Transmission 2 Transmission 3 Transmission 4 1) 2) 3) 4)=2) MSB 0611h LSB MSB 0610h LSB MSB 0611h LSB |
|
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |