| Datenblatt-Suchmaschine für elektronische Bauteile |
|
LD1071 Datenblatt(PDF) 21 Page - LDT Co., Ltd |
|
|
|||||||||||||||||||||||||||||
LD1071 Datenblatt(HTML) 21 Page - LDT Co., Ltd |
|
21 / 36 page ![]() Ver1.0 21 LD1071 16 Channel Output LED Driver with 14 bit PWM Controller Error Detection Code Open Check Output Port status Error Detection Voltage Meaning OFF OUT Voltage > 0.8V Normal OUT Voltage < 0.8V Open Error Short Check OFF OUT Voltage > 0.8V Normal OUT Voltage < 0.8V Short Error Error Status Register ( ER[15:0] ) bit15 bit14 bit13 bit12 bit11 bit10 bit9 bit8 bit7 bit6 bit5 bit4 bit3 bit2 bit1 bit0 OUT15 OUT14 OUT13 OUT12 OUT11 OUT10 OUT9 OUT8 OUT7 OUT6 OUT5 OUT4 OUT3 OUT2 OUT1 OUT0 16 bit Shifter Register DOUT Error Status Read Command 0 : Normal 1 : Open or Short Error - Open Error : Output port( OUTn ) is not connected to LED. - Short Error : Output port( OUTn ) is shorted to GND. ERROR DETECTION The LD1071 will be able to detect the error status of LED such as open/short error. This function can be entered by setting the bits of Error Detection Mode( CR[9:8] ) as 01b( Open Detection ) or 10b( Short Detection ). The correct meaning of error is defined as follows; Timing Diagram of Error Status Check Note *1) In order to keep the Constant Current Value( CR[7:0] ) and Global Latch Mode( CR[10] ) correctly, maybe you need to read the Configuration Register through the Configuration Register Read Command( 0038h ) prior to set Error Detection Mode. CLOCK DIN STROBE DOUT PWMCK OUTn Previous Data 2 115 16 1 2 15 16 C1 C0 C15 D1 D0 D15 2 13 4 13 14 15 16 C1 C0 C3 12 3 15 16 14 Don’t Care ER15 ER14 ER13 ER1 ER0 Error Status Read Command Set Error Detection Mode 0034h 003Ch D[9:8] *1) Actual Read Operation The next timing diagram shows the sequence of error status read operation. The actual error status is read with MSB first after execution of Error Status Read Command. First of all, in order to read the error status, all the output ports (OUT15~OUT0) should be off. So you need some pre-processing for error status read. The flow chart will be provided on next page. C13 C15 C2 C14 |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |