| Datenblatt-Suchmaschine für elektronische Bauteile |
|
LBA127LS Datenblatt(PDF) 5 Page - Clare, Inc. |
|
|
|||||||||||||||||||||||||||||
LBA127LS Datenblatt(HTML) 5 Page - Clare, Inc. |
|
5 / 7 page ![]() LBA127L www.clare.com 5 Rev. 4 PERFORMANCE DATA* *The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. LBA127L - Form A Typical Current Limiting vs. Temperature IF = 5mADC Temperature ( °C) 400 350 300 250 200 150 100 50 0 -40 -20 0 20 40 60 80 120 100 LBA127L - Form B Typical Turn-On vs. LED Forward Current (Load Current = 170mADC) LED Forward Current (mA) 0 5 1015202530354045 0.06 0.05 0.04 0.03 0.02 0.01 50 LBA127L - Form A Typical Turn-Off vs. LED Forward Current (Load Current = 170mADC) LED Forward Current (mA) 0 5 1015202530354045 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0 50 LBA127L - Form B Typical Turn-Off vs. LED Forward Current (Load Current = 170mADC) LED Forward Current (mA) 0 5 1015202530354045 1.6 1.4 1.2 1.0 0.8 0.6 50 LBA127L - Form A Typical On-Resistance vs. Temperature (Load Current = 170mADC; IF = 5mADC) Temperature ( °C) -40 60 50 40 30 20 10 0 -20 0 20 40 60 80 100 LBA127L - Form B Typical On-Resistance vs. Temperature (Load Current = 170mADC; IF = 5mADC) Temperature ( °C) -40 -20 0 20 40 60 80 100 9 8 7 6 5 4 3 2 1 0 LBA127L - Form A Typical IF for Switch Operation vs. Temperature (Load Current = 170mADC) Temperature ( °C) -40 3.0 2.5 2.0 1.5 1.0 0.5 0 -20 0 20 40 60 80 100 LBA127L - Form B Typical IF for Switch Operation vs. Temperature (Load Current = 170mADC) Temperature ( °C) -40 4.500 4.000 3.500 3.000 2.500 2.000 1.500 -20 0 20 40 60 80 100 LBA127L - Form A Typical IF for Switch Dropout vs. Temperature (Load Current = 170mADC) Temperature ( °C) -40 3.0 2.5 2.0 1.5 1.0 0.5 0 -20 0 20 40 60 80 100 LBA127L - Form B Typical IF for Switch Dropout vs. Temperature (Load Current = 170mADC) Temperature ( °C) -40 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0 -20 0 20 40 60 80 100 LBA127L - Form A Typical Load Current vs. Load Voltage (Ambient Temperature = 25 °C; IF = 5mADC) Load Voltage (V) 200 150 100 50 0 -50 -100 -150 -200 -1.5 -2.0 -2.5 -0.5 -1.0 0 0.5 1.0 1.5 2.0 2.5 LBA127L - Form B Typical Load Current vs. Load Voltage (Ambient Temperature = 25 °C; IF = 5mADC) Load Voltage (V) 200 150 100 50 0 -50 -100 -150 -200 -1.0 -0.6 -0.2 -0.4 -0.8 0 0.2 0.4 0.6 0.8 1.0 LBA127L Energy Rating Curve Time 10 µs 1.2 1.0 0.8 0.6 0.4 0.2 0 1ms 100 µs 100ms 1s 10ms 10s 100s |
|
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |