| Datenblatt-Suchmaschine für elektronische Bauteile |
|
ADE7754 Datenblatt(PDF) 13 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADE7754 Datenblatt(HTML) 13 Page - Analog Devices |
|
13 / 44 page ![]() REV. 0 ADE7754 –13– In addition to the enable bits, the zero-crossing detection interrupt of each phase is enabled/disabled by setting the ZXSEL bits of the MMODE register (Address 0Bh) to Logic 1 or 0, respectively. Zero-Crossing Timeout Each zero-crossing detection has an associated internal timeout register (not accessible to the user). This unsigned, 16-bit regis- ter is decremented (1 LSB) every 384/CLKIN seconds. The registers are reset to a common user programmed value (i.e., zero cross timeout register—ZXTOUT, Address 12h) every time a zero crossing is detected on its associated input. The default value of ZXTOUT is FFFFh. If the internal register decrements to zero before a zero crossing at the corresponding input is detected, it indicates an absence of a zero crossing in the time determined by the ZXTOUT. The ZXTO detection bit of the corresponding phase in the interrupt status register is then switched on (Bits 4 to 6). An active low on the IRQ output also appears if the SAG enable bit for the corresponding phase in the interrupt enable register is set to Logic 1. In addition to the enable bits, the zero-crossing timeout detec- tion interrupt of each phase is enabled/disabled by setting the ZXSEL bits of the MMODE register (Address 0Bh) to Logic 1 or Logic 0, respectively. When the zero-crossing timeout detection is disabled by this method, the ZXTO flag of the corresponding phase is switched on all the time. Figure 15 shows the mechanism of the zero-crossing timeout detection when the line voltage A stays at a fixed dc level for more than CLKIN/384 ZXTOUT seconds. VOLTAGE CHANNEL A ZXTOA DETECTION BIT 16-BIT INTERNAL REGISTER VALUE ZXTOUT Figure 15. Zero-Crossing Timeout Detection PERIOD MEASUREMENT The ADE7754 also provides the period measurement of the line voltage. The period is measured on the phase specified by Bits 0 to 1 of the MMODE register. The period register is an unsigned 15-bit register and is updated every period of the selected phase. Bits 0 and 1 and Bits 4 to 6 of the MMODE register select the phase for the period measurement; both selections should indicate the same phase. The ZXSEL bits of the MMODE register (Bits 4 to 6) enable the phases on which the period measurement can be done. The PERDSEL bits select the phase for period measurement within the phases selected by the ZXSEL bits. The resolution of this register is 2.4 µs/LSB when CLKIN = 10 MHz, which is 0.014% when the line frequency is 60 Hz. When the line frequency is 60 Hz, the value of the period regis- ter is approximately 6944d. The length of the register enables the measurement of line frequencies as low as 12.7 Hz. LINE VOLTAGE SAG DETECTION The ADE7754 can be programmed to detect when the absolute value of the line voltage of any phase drops below a certain peak value for a number of half cycles. All phases of the voltage chan- nel are controlled simultaneously. This condition is illustrated in Figure 16. SAGCYC[7:0] = 06h 6 HALF CYCLES SAGLVL[7:0] FULL SCALE SAG INTERRUPT FLAG (BIT 1 TO BIT 3 OF STATUS REGISTER) SAG EVENT RESET LOW WHEN VOLTAGE CHANNEL EXCEEDS SAGLVL[7:0] READ RSTATUS REGISTER VAP, VBP, OR VCP Figure 16. SAG Detection Figure 16 shows a line voltage falling below a threshold set in the SAG level register (SAGLVL[7:0]) for nine half cycles. Since the SAG cycle register indicates a six half-cycle thresh- old (SAGCYC[7:0]=06h), the SAG event is recorded at the end of the sixth half-cycle by setting the SAG flag of the corre- sponding phase in the interrupt status register (Bits 1 to 3 in the interrupt status register). If the SAG enable bit is set to Logic 1 for this phase (Bits 1 to 3 in the interrupt enable register), the IRQ logic output goes active low. See the Interrupts section. All the phases are compared to the same parameters defined in the SAGLVL and SAGCYC registers. SAG Level Set The content of the SAG level register (one byte) is compared to the absolute value of the most significant byte output from the voltage channel ADC. Thus, for example, the nominal maximum code from the voltage channel ADC with a full-scale signal is 28F5h. See the Voltage Channel ADC section. Therefore, writing 28h to the SAG level register puts the SAG detection level at full scale and sets the SAG detection to its most sensitive value. Writing 00h puts the SAG detection level at 0. The detection of a decrease of an input voltage is in this case hardly possible. The detection is made when the content of the SAGLVL register is greater than the incoming sample. PEAK DETECTION The ADE7754 also can be programmed to detect when the absolute value of the voltage or the current channel of one phase exceeds a certain peak value. Figure 17 illustrates the behavior of the peak detection for the voltage channel. |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |