| Datenblatt-Suchmaschine für elektronische Bauteile |
|
AN4313 Datenblatt(PDF) 5 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
AN4313 Datenblatt(HTML) 5 Page - STMicroelectronics |
|
5 / 15 page ![]() DocID024816 Rev 1 5/15 AN4313 Projected sensor design 14 2 Projected sensor design 2.1 Touchkey sensor The touchkey sensor can be of any shape, however it is recommended to use a square as this shape is the simplest. The touch sensing library and ProxSenseTM IP automatically compensate for capacitance differences, but the acquisition time and processing parameters can be optimized if the sensors have a similar capacitance. For this reason, it is recommended to use the same shape for all sensors. The physical principlefor a touchkey, linear or rotary sensor is that an electric field surrounds the Tx and Rx electrodes (see Figure 1). This field is dependent on the permittivity R of both the front panel and the PCB. It should not be dependent on air bubbles or moisture which can be trapped between them, because they must be sufficiently well bonded by the adhesive. Figure 1. Electric field between 2 surface electrodes 1. The above figure only shows a simplified representation of the sensor; for specification details, refer to Figure 2 to Figure 4. Hence, the sensitivity is dependent on known materials and is optimized. This will ensure that the disturbance caused by the user’s finger is detected and measured with accuracy. It is recommended to define the sensor size in relation to the panel thickness (d) and vice- versa. The following formula helps the designer to define the external size of touchkey sensors (L), and also for linear touch sensor and rotary touch sensor parcels: L (mm) = 3 + (1.75 * d) For example, a typical 10*10 mm touchkey should be used with a 4 mm Plexiglas panel. 2.1.1 Diamond type sensor In this “diamond type” implementation, the Tx and Rx electrodes form a diamond shape where the two electrodes are on the same layer, using a bridge (see Figure 2). Note: This symmetrical implementation allows swapping Rx & Tx. MS18983V1 Dielectric panel Electric field Electrodes Electric field Electrodes |
|
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |