| Datenblatt-Suchmaschine für elektronische Bauteile |
|
CPC7695 Datenblatt(PDF) 21 Page - IXYS Corporation |
|
|
|||||||||||||||||||||||||||||
CPC7695 Datenblatt(HTML) 21 Page - IXYS Corporation |
|
21 / 25 page ![]() INTEGRATED CIRCUITS DIVISION CPC7695 R01 www.ixysic.com 21 Although battery power is not used for switch control, it is required to supply trigger current for the integrated internal protection circuitry SCR during fault conditions. This integrated SCR is designed to activate whenever the voltage at TBAT or RBAT drops 2V to 4V below the applied voltage on the VBAT pin. Because the battery supply at this pin is required to source trigger current during negative overvoltage fault conditions at tip and ring, it is important that the net supplying this current be a low impedance path for high speed transients such as lightning. This will permit trigger currents to flow enabling the SCR to activate and thereby prevent a fault induced negative overvoltage event at the TBAT or RBAT nodes. 2.10 Protection 2.10.1 Current Limiting Function If a lightning strike transient occurs when the device is in theTalk state, the current is passed along the line to the integrated protection circuitry and restricted by the dynamic current limit response of the active switches. During theTalk state when a 1000V 10x1000 S pulse (GR-1089-CORE lightning) is applied to the line though a properly clamped external protector, the current seen at TLINE or RLINE will be a pulse with a typical magnitude of 2.5A and a duration of less than 0.5 s. If a power-cross fault occurs with the device in theTalk state, the current is passed though the break switches SW1 and SW2 on to the integrated protection circuit but is limited by the dynamic DC current limit response of the two break switches. The DC current limit specified over temperature is between 80mA and 425mA, and the circuitry has a negative temperature coefficient. As a result, if the device is subjected to extended heating due to a power-cross fault condition, the measured current into TLINE or RLINE will decrease as the device temperature increases. If the device temperature rises sufficiently, the thermal shutdown mechanism will activate and the device will enter the All-Off state. 2.10.2 Diode Bridge/SCR The CPC7695 uses a combination of current limited break switches, a diode bridge/SCR clamping circuit, and a thermal shutdown mechanism to protect the SLIC device and other associated circuitry from damage during line transient events such as lightning. During a positive transient condition, the fault current is conducted through the diode bridge to ground via FGND. Voltage is clamped to a diode drop above ground. During a negative transient of 2V to 4V more negative than the voltage source at VBAT, the SCR conducts and faults are shunted to FGND via the SCR. Devices utilizing the diode bridge will steer negative transients to VBAT. In order for the SCR to crowbar or foldback, the SCR’s on-voltage (see “Protection Circuitry Electrical Specifications” on page 14) must be less than the applied voltage at the VBAT pin. If the VBAT voltage is less negative than the SCR on-voltage, or if the VBAT supply is unable to source the trigger current, the SCR will not crowbar. For power induction or power-cross fault conditions, the positive cycle of the transient is clamped to a diode drop above ground and the fault current is directed to ground. The negative cycle of the transient will cause the SCR to conduct when the voltage exceeds the VBAT reference voltage by two to four volts, steering the fault current to ground. Note: The CPC7695xB does not contain a protection SCR but instead utilizes a diode bridge to clamp both polarities of a fault transient. These diodes pass the charge of negative fault potentials to the VBAT pin. 2.10.3 Thermal Shutdown The thermal shutdown mechanism will activate when the device die temperature reaches a minimum of 110°C, placing the device in the All-Off state regardless of INRINGING, INTESTin and INTESTout logic inputs. During thermal shutdown events the TSD pin will output a logic low with a nominal 0V level. A logic high is output from the TSD pin during normal operation with a typical output level equal to VDD. If presented with a short duration transient such as a lightning event, the thermal shutdown feature will typically not activate. But in an extended power-cross event, the device temperature will rise and the thermal shutdown mechanism will activate forcing the switches to the All-Off state. At this point the current measured into TLINE or RLINE will drop to zero. Once the device enters thermal shutdown it will remain in the All-Off state until the temperature of the die drops below the deactivation level of the thermal shutdown circuit. This permits the device to return to normal operation. If the |
|
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |