9 / 28 page ![]() 1.0 Functional Description (Continued) cleared only upon a read command from the master (see Figure 4 ) and will be re-asserted at the end of the next conversion if the triggering condition(s) persist(s). In order for the ALERT to be used as a dedicated interrupt signal, the Comparator Mode bit in the Remote Diode Temperature Filter and Comparator Mode Register must be set low. This is the power-on default state. The following sequence de- scribes the response of a system that uses the ALERT output pin as an interrupt flag: 1. Master senses ALERT low. 2. Master reads the LM63 ALERT Status Register to deter- mine what caused the ALERT. 3. LM63 clears ALERT Status Register, resets the ALERT HIGH and sets the ALERT Mask bit in the Configuration Register. 4. Master attends to conditions that caused the ALERT to be triggered. The fan is started, setpoint limits are ad- justed, etc. 5. Master resets the ALERT Mask bit in the Configuration Register. 1.2.3 ALERT Output as an SMBus ALERT An SMBus alert line is created when the ALERT output is connected to: (1) one or more ALERT outputs of other SMBus compatible devices, and (2) to a master. Under this implementation, the LM63’s ALERT should be operated us- ing the ARA (Alert Response Address) protocol. The SMBus 2.0 ARA protocol, defined in the SMBus specification 2.0, is a procedure designed to assist the master in determining which part generated an interrupt and to service that inter- rupt. The SMBus alert line is connected to the open-drain ports of all devices on the bus, thereby AND’ing them together. The ARA method allows the SMBus master, with one command, to identify which part is pulling the SMBus alert line LOW. It also prevents the part from pulling the line LOW again for the same triggering condition. When an ARA command is re- ceived by all devices on the bus, the devices pulling the SMBus alert line LOW: (1) send their address to the master and (2) release the SMBus alert line after acknowledgement of their address. The SMBus Specifications 1.1 and 2.0 state that in response to and ARA (Alert Response Address) “after acknowledging the slave address the device must disengage its ALERT pulldown”. Furthermore, “if the host still sees ALERT low when the message transfer is complete, it knows to read the ARA again.” This SMBus “disengaging ALERT requirement prevents locking up the SMBus alert line. Competitive parts may address the “disengaging of ALERT” differently than the LM63 or not at all. SMBus systems that implement the ARA protocol as suggested for the LM63 will be fully compatible with all competitive parts. The LM63 fulfills “disengaging of ALERT” by setting the ALERT Mask Bit in the Configuration Register after sending out its address in response to an ARA and releasing the ALERT output pin. Once the ALERT Mask bit is activated, the ALERT output pin will be disabled until enabled by software. In order to enable the ALERT the master must read the ALERT Status Register, during the interrupt service rou- tine and then reset the ALERT Mask bit in the Configuration Register to 0 at the end of the interrupt service routine. The following sequence describes the ARA response proto- col. 1. Master senses SMBus alert line low 2. Master sends a START followed by the Alert Response Address (ARA) with a Read Command. 3. Alerting Device(s) send ACK. 4. Alerting Device(s) send their address. While transmitting their address, alerting devices sense whether their ad- dress has been transmitted correctly. (The LM63 will reset its ALERT output and set the ALERT Mask bit once its complete address has been transmitted successfully.) 5. Master/slave NoACK 6. Master sends STOP 7. Master attends to conditions that caused the ALERT to be triggered. The ALERT Status Register is read and fan started, setpoints adjusted, etc. 8. Master resets the ALERT Mask bit in the Configuration Register. The ARA, 000 1100, is a general call address. No device should ever be assigned to this address. The ALERT Configuration bit in the Remote Diode Tempera- ture Filter and Comparator Mode Register must be set low in order for the LM63 to respond to the ARA command. The ALERT output can be disabled by setting the ALERT Mask bit in the Configuration Register. The power-on default is to have the ALERT Mask bit and the ALERT Configuration bit low. 20057008 FIGURE 4. ALERT Output as an Interrupt Temperature Response Diagram www.national.com 9 |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |