16 / 24 page ![]() 16 Digital Temperature Controllers E5CN/E5CN-U ■ Parameters Operation Level Manual Control Level Power ON Adjustment Level Protect Level Communications Setting Level a-m m-sp 0 25 C 25 0 C sp-m 0 C ct1 0.0 ct2 0.0 lcr1 0.0 lcr2 0.0 prst rset sktr 0 r-s run al-1 0 C al1h 0 C al1l 0 C al-2 0 C al2h 0 C al2l 0 C al-3 0 C al3h 0 C al3l 0 C o 0.0 c-o 0.0 Process value Added when PV display is added. Process value/ set point Multi-SP set point setting SP ramp monitor Heater current value 1 monitor Heater current value 2 monitor Leakage current value 1 monitor Leakage current value 2 monitor Program start Remaining soak time monitor Run/stop Alarm value 1 Upper-limit alarm value 1 Lower-limit alarm value 1 Alarm value 2 Upper-limit alarm value 2 Lower-limit alarm value 2 Alarm value 3 Upper-limit alarm value 3 Lower-limit alarm value 3 MV monitor (heating) MV monitor (cooling) cmwt off ct1 0.0 l.adj at off ct2 0.0 lcr1 0.0 lcr2 0.0 hb1 0.0 hb2 0.0 hs1 50.0 hs2 50.0 sp-0 0 C sp-1 0 C sp-2 0 C sp-3 0 C ins 0.0 C insh 0.0 C p 8.0 C i 233 d 40 c-sc 1.00 c-db 0.0 C of-r 50.0 hys 1.0 C chys 1.0 C soak 1 wt-b off C mV-s 0.0 mV-e 0.0 sprt off C ol-h 105.0 ol-l -5.0 AT execute/cancel Communications writing SSR failure detection 1 SSR failure detection 2 SP 0 SP 1 SP 2 SP 3 Temperature input shift Proportional band Integral time Derivative time Cooling coefficient Dead band Manual reset value Hysteresis (heating) Hysteresis (cooling) Soak time Wait band MV at stop MV at PV error SP ramp set value MV upper limit MV lower limit Protocol setting Communications Unit No. Baud rate Data bits Stop bits Communications parity Send delay psel cwf u-no 1 bps 9.6 len 7 sbit 2 prty eVen sdwt 20 pmoV 0 oapt 0 icpt 1 wtpt off pmsk on prlp 0 Move to protect level Operation/adjustment protection Initial Setting/ Communications Protection Setting change protection Parameter mask enable Password to move to protect level Password setting Press the Level Key less than 1 s. Press the Level Key less than 1 s. Press the Level Key for at least 3 s. (Display flashes for at least 1 s.) Displays other than that for switching between automatic and manual Starting in automatic mode Starting in manual mode 25 C PV/MV PID control only insl 0.0 C SP used by multi-SP Set either of these parameters. PID settings Heating/cooling Hysteresis settings 1-point shift 2-point shift CompoWay/F (SYSWAY) only Auto/manual switch PID control only Added when auto/manual switching function is added. Press the Level Key for at least 1 s. Adjustment level display Displayed only once when entering adjustment level. a Heater current value 1 monitor Heater current value 2 monitor Leakage current value 1 monitor Leakage current value 2 monitor Heater burnout 1 detection Heater burnout 2 detection Upper-limit temperature input Lower-limit temperature input Clear the offset during stabilization of P or PD control. Press the Level Key for at least 3 s. (Display flashes for at least 1 s.) Press the Level + Mode Keys for at least 3 s. Display flashes. The time taken to move to the protect level can be adjusted by changing the "Move to protect level time" setting. Displayed only when a password is set. Restricts moving to protect level. Restricts displaying and modifying menus in operation, adjustment, and manual control levels. This protect level restricts movement to the initial setting, communications setting, and advanced function setting levels. Protects changes to setups by operating the front panel keys. Displayed only when a parameter mask is set. Switches between CompoWay/F (SYSWAY) and Modbus. Displayed only for models with communications. Changes are effective after cycling power or after a software reset. Press the Level + Mode Keys for at least 1 s. Press the Level Key less than 1 s. a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a Some parameters are not displayed depending on the model of the Controller and parameter settings. For details, refer to the E5CN/E5CN-U Temperature Controller User's Manual (Cat. No. H129) |
|
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |