| Datenblatt-Suchmaschine für elektronische Bauteile |
|
E5CN-R2TU Datenblatt(PDF) 22 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E5CN-R2TU Datenblatt(HTML) 22 Page - Omron Electronics LLC |
|
22 / 24 page ![]() 22 Digital Temperature Controllers E5CN/E5CN-U Precautions for Correct Use Service Life 1. Use the Temperature Controller within the following temperature and humidity ranges: Temperature: -10 to 55°C (with no icing or condensation) Humidity: 25% to 85% If the Controller is installed inside a control board, the ambient temperature must be kept to under 55 °C, including the temperature around the Controller. 2. The service life of electronic devices like Temperature Controllers is determined not only by the number of times the relay is switched but also by the service life of internal electronic components. Component service life is affected by the ambient temperature: the higher the temperature, the shorter the service life and, the lower the temperature, the longer the service life. Therefore, the service life can be extended by lowering the temperature of the Temperature Controller. 3. When two or more Temperature Controllers are mounted horizontally close to each other or vertically next to one another, the internal temperature will increase due to heat radiated by the Temperature Controllers and the service life will decrease. In such a case, use forced cooling by fans or other means of air ventilation to cool down the Temperature Controllers. When providing forced cooling, however, be careful not to cool down the terminals sections alone to avoid measurement errors. Measurement Accuracy 1. When extending or connecting the thermocouple lead wire, be sure to use compensating wires that match the thermocouple types. 2. When extending or connecting the lead wire of the platinum resistance thermometer, be sure to use wires that have low resistance and keep the resistance of the three lead wires the same. 3. Mount the Temperature Controller so that it is horizontally level. 4. If the measurement accuracy is low, check to see if input shift has been set correctly. Waterproofing The degree of protection is as shown below. Sections without any specification on their degree of protection or those with IP @0 are not waterproof. Front panel: NEMA4X for indoor use (equivalent to IP66) Rear case: IP20, Terminal section: IP00 (E5CN-U: Front panel: Equivalent to IP50, rear case: IP20, terminals: IP00) Operating Precautions 1. It takes approximately two seconds for the outputs to turn ON from after the power supply is turned ON. Due consideration must be given to this time when incorporating Temperature Controllers in a sequence circuit. 2. When using self-tuning, turn ON power for the load (e.g., heater) at the same time as or before supplying power to the Temperature Controller. If power is turned ON for the Temperature Controller before turning ON power for the load, self-tuning will not be performed properly and optimum control will not be achieved. 3. When starting operation after the Temperature Controller has warmed up, turn OFF the power and then turn it ON again at the same time as turning ON power for the load. (Instead of turning the Temperature Controller OFF and ON again, switching from STOP mode to RUN mode can also be used.) Avoid using the Controller in places near a radio, television set, or wireless installing. 4. These devices can cause radio disturbances which adversely affect the performance of the Controller. Mounting Mounting to a Panel 1. To mount the Controller so that it is waterproof, insert the waterproof packing onto the Controller. Group mounting does not allow waterproofing. The waterproof packing is not required if waterproofing is not necessary. The Panel Mounting Adapter is also included with the E5CN-U. Waterproof packing is not included with the E5CN-U. 2. Insert the E5CN/E5CN-U into the mounting hole in the panel. 3. Push the adapter along the Controller body from the terminals up to the panel, and fasten it temporarily. 4. Tighten the two fixing screws on the adapter. Alternately tighten the two screws a little at time to keep them balanced. Tighten them to a torque of 0.29 to 0.39 N·m. Attaching the Terminal Cover Make sure that the “UP” letters on the E5CN are at the top and insert the terminal cover into the holes at the top and bottom of the Controller. Removing the Controller from the Case When carrying out maintenance on the Controller, the Controller can be removed from the case with the terminal leads still attached. The Controller can be removed from the case only with the E5CN. It cannot be removed with the E5CN-U. 1. Insert the tool into the slots (one on the top and one on the bottom) and release the hooks. 2. Insert the tool into the gap between the front panel and rear case and pull out the front panel slightly. Hold both sides of the front panel and draw out the Controller towards you. Do not apply unnecessary force. 3. Before inserting the Controller, confirm that the sealing rubber is in place. Insert the Controller into the rear case until you hear a click. Press on the hooks on the top and bottom of the rear case to be sure that the hooks are securely locked in place.Be sure that electronic parts do not come in contact with the case. Terminal Cover (order separately) Mounting Adapter (Accessory) E5CN E5CN-U Waterproof packing Panel Order the P2CF-11 or P3GA-11 Socket separately. Front-mounting Socket (Panel mounting is also possible.) E5CN PV SV ALM1 ALM2 ALM 3 HA OUT1 STO P OUT2 CMW MANU (1) (1) (2) (3) Tool insertion hole Flat-blade screwdriver (Unit: mm) |
|
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |