14 / 30 page ![]() TSC2003 14 SBAS162G www.ti.com BATTERY MEASUREMENT An added feature of the TSC2003 is the ability to monitor the battery voltage on the other side of the voltage regulator (DC/DC converter), as shown in Figure 7. The battery voltage can vary from 0.5V to 6V, while the voltage regulator main- tains the voltage to the TSC2003 at 2.7V, 3.3V, etc. The input voltage (VBAT1 or VBAT2) is divided down by 4 so that a 6.0V battery voltage is represented as 1.5V to the A/D converter. The simplifies the multiplexer and control logic. In order to minimize the power consumption, the divider is only ON during the sample period which occurs after control bits C3 = 0, C2 = 0, C1 = 0, and C0 = 1 (VBAT1) or C3 = 0, C2 = 1, C1 = 0, and C0 = 1 (VBAT2) are received. See Tables I and II for the relationship between the control bits and configura- tion of the TSC2003. VDD VBAT 7.5k Ω 2.5k Ω DC/DC Converter Battery 0.5V to 6.0V 0.125V to 1.5V 2.7V + A/D Converter FIGURE 7. Battery Measurement Functional Block Diagram. X-Position Measure X-Position Measure Z 1-Position Touch X+ Y+ X– Y– Z 1-Position Touch X+ Y+ Y– X– Measure Z 2-Position Z 2-Position Touch X+ Y+ Y– X– FIGURE 8. Pressure Measurement Block Diagrams. PRESSURE MEASUREMENT Measuring touch pressure can also be done with the TSC2003. To determine pen or finger touch, the pressure of the “touch” needs to be determined. Generally, it is not necessary to have high accuracy for this test, therefore, the 8-bit resolution mode is recommended. However, calculations will be shown with the 12-bit resolution mode. There are several different ways of performing this measurement—the TSC2003 sup- ports two methods. The first method requires knowing the X-Plate resistance, measurement of the X-Position, and two additional cross-panel measurements (Z2 and Z1) of the touch screen, as shown in Figure 8. Using Equation 2 will calculate the touch resistance: RR X Position 4096 Z Z – 1 TOUCH X Plate 2 1 =• − − (2) The second method requires knowing both the X-Plate and Y-Plate resistance, measurement of X-Position and Y-Posi- tion, and Z1. Equation 3 calculates the touch resistance using the second method: R R X Position 4096 4096 Z – 1 –R Y Position 4096 TOUCH X Plate 1 Y Plate = − • − − • − 1– (3) DIGITAL INTERFACE The TSC2003 supports the I2C serial bus and data transmis- sion protocol in all three defined modes: standard, fast, and high-speed. A device that sends data onto the bus is defined as a transmitter, and a device receiving data as a receiver. The device that controls the message is called a master. The devices that are controlled by the master are slaves. The bus must be controlled by a master device which generates the |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |