| Datenblatt-Suchmaschine für elektronische Bauteile |
|
TDA7333N Datenblatt(PDF) 22 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
TDA7333N Datenblatt(HTML) 22 Page - STMicroelectronics |
|
22 / 36 page ![]() Functional description TDA7333N 22/36 3.8.2 rds_qu register 3.8.3 rds_corrp register (2) If "syncw" =1 of rds_bd_ctrl register, the block counter in- dicates the expected RDS block. (3) qu[3...0] counts the number of bits (max.16) which are marked as bad by the demodulator within each RDS block. It could be used as a quality information, indicating the max- imum number of bits which are allowed to be corrected. It indicates if error correction was successful. 1: The syndrome was zero after error correction. 0: The syndrome did not become zero and therefore the error correction was not successful. 1: Block E is detected. This indicates a paging block which is deÞned in the RBDS speciÞcation used in the United States of America. 0: An ordinary RDS block A, B, C, C« or D is detected, or no valid syndrome was found. Bit 0 of block counter (2). bit 1 of block counter (2). bit 0 of quality counter (3). bit 1 of quality counter (3). bit 2 of quality counter (3). bit 3 of quality counter (3). bit name access bit 7 bit 0 bit 1 bit 2 bit 3 bit 4 bit 5 bit 6 r r rr rrr r synz e qu0 qu3 qu1 qu2 blk1 blk0 blk1 1 0 0 0 blk0 block A block name block D 1 block C,C' 0 block B 1 1 (2) reset value 0 0 00 00 0 0 rds_qu (4) (Refer to CENELEC Radio Data System speciÞcation EN50067, ANNEX B). When bits 0...4 of the syndrome reg- ister are zero, a possible error burst is detected. With help of the correction pattern (bits 5...9 of the syndrome register), the type of error can be measured, in order to classify the reliability of the correction. Buffer overflow 1: More than 24 blocks have been written into the buffer. 0: No buffer data has been overwritten. Information if the current RDS data could be used. 1: A correct syndrome was detected and no error correction was done on a good quality marked RDS bit and the flywheel counter is greater than 2 (RDS data is OK). 0: The syndrome was wrong, or an error correction was done on a good quality marked RDS bit, or the flywheel counter is lower than 3 (RDS data is not OK). It is an information about error correction. 1: An error correction was done. 0: The actual RDS block is detected as error free. bit 5 of the syndrome register(4). bit 6 of the syndrome register(4). bit 7 of the syndrome register(4). bit 8 of the syndrome register(4). bit 9 of the syndrome register(4). bit name access bit 7 bit 0 bit 1 bit 2 bit 3 bit 4 bit 5 bit 6 r r rr rr r r bovf dat_ok cp6 cp9 cp7 cp8 cp5 correct reset value 0 0 00 00 0 0 rds_corrp |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |