| Datenblatt-Suchmaschine für elektronische Bauteile |
|
THMC50SSOPDBQ Datenblatt(PDF) 22 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
THMC50SSOPDBQ Datenblatt(HTML) 22 Page - Texas Instruments |
|
22 / 32 page ![]() THMC50 REMOTE/LOCAL TEMPERATURE MONITOR AND FAN CONTROLLER WITH SMBus INTERFACE SLIS090 – JULY 1999 22 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 PRINCIPLES OF OPERATION interrupt clearing (continued) The INT output can be cleared with the INT clear bit (bit 2 of the configuration register) without affecting the contents of the interrupt status register. reset generators The THMC50 contains the equivalent of two MAX811 microprocessor voltage monitors for generation of system resets. One of these functions monitors the THMC50 VCC3 terminal connected to the system’s 3.3-V main power supply. The other function monitors the VCC3AUX terminal connected to the system’s 3.3-V auxiliary power supply. Each function has a corresponding reset output (RST, AUXRST) that is used by the core logic for proper system hardware initialization. When a particular power supply voltage falls below a threshold of 2.93V (max), the associated reset output is asserted low for at least 140 ms after the power supply voltage has risen above the threshold (see Figure 18 and Figure 20). The reset outputs are a logic 0 for VCC (VCC3 or VCC3AUX) > 1 V. The THMC50 includes a manual reset input, MR. When asserted low (0), the RST output is asserted low. This output remains asserted as long as the MR input is asserted. Once MR is negated, this reset output continues to be asserted for 180 ms (typical) (see Figure 17). The MR input may be used by test equipment or external logic (e.g., front bezel panel reset button) to initiate a reset independent of power supply voltage status. It is recommended that a 0.1- µF capacitor be connected between MR and ground if the terminal is connected to a long lead/cable length. Asserting the AUXRST output causes the RST output to also be asserted regardless of the voltage level on the VCC3 terminal. This insures that the auxiliary reset output (AUXRST) is negated before the RST output is negated. Once AUXRST is negated, the RST output continues to remain asserted for 180 ms (typical) (see Figure 19). The AUXRST terminal is bidirectional. It can be driven by an external device to force the THMC50 into a hard reset condition. Insure that other devices connected to AUXRST are not also reset, if that is an undesirable behavior. If AUXRST is only used as an output, then isolation is not necessary. reset generators timing diagrams Figure 17 through Figure 20 illustrate the timing relationship of the THMC50 reset generators. D Figure 17 shows RST output behavior when the MR input is asserted low. D Figure 18 shows RST output behavior according to the voltage seen at the VCC3 terminal. D Figure 19 shows RST output behavior whenever an AUXRST is generated or is asserted manually. D Figure 20 shows AUXRST output and RST output behavior according to the voltage seen at the VCC3AUX terminal. Figure 17. MR to RST Timing Figure 18. VCC3 to RST Timing MR RST TIME t(RP) t(MR) VCC3 RST 2.93V TIME t(RP) t(VCC3RST) |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |