| Datenblatt-Suchmaschine für elektronische Bauteile |
|
THMC50SSOPDBQ Datenblatt(PDF) 25 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
THMC50SSOPDBQ Datenblatt(HTML) 25 Page - Texas Instruments |
|
25 / 32 page ![]() THMC50 REMOTE/LOCAL TEMPERATURE MONITOR AND FAN CONTROLLER WITH SMBus INTERFACE SLIS090 – JULY 1999 25 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 PRINCIPLES OF OPERATION register 0x41 interrupt status register power-on default <7:0> = 00h BIT NAME READ/WRITE DESCRIPTION 0 Ambient temperature error Read only A 1 indicates one of the ambient temperature limits has been exceeded. 1 Reserved Read only Undefined (reserved for remote thermal diode 2 temperature error) 2 Reserved Read only Undefined (reserved for remote thermal diode 2 fault) 3 Reserved Read only Undefined 4 GPI input Read only A 1 indicates that the GPI terminal is asserted. The polarity of the GPI terminal is determined by GPI invert (bit 6) in the configuration register. For example, if GPI invert is cleared, then this bit is 1 when the GPI terminal is high (1); this bit is 0 when the GPI terminal is low (0). If GPI invert is set, then this bit is 1 when the GPI terminal is low (0); this bit is 0 when the GPI terminal is high (1). Note: The state of GPI is not latched; this bit simply reflects the state or inverted state of the GPI terminal. If this bit is 1, reading this register does not clear it to 0. 5 Remote temperature error Read only A 1 indicates one of the remote thermal diode limits has been exceeded. 6 THERM input Read only A 1 indicates that the thermal overload (THERM) line has been asserted externally. 7 Remote diode fault Read only A 1 indicates either a short or open circuited fault on the remote thermal diode inputs. NOTE: An error that causes continuous interrupts to be generated may be masked in its respective mask register, until the error can be alleviated. register 0x43 interrupt mask register power-on default <7:0> = 00h BIT NAME READ/WRITE DESCRIPTION 0 Ambient temperature error Read/write A 1 disables the corresponding interrupt status bit for the INT output. 1 Reserved Read only Undefined (reserved for remote thermal diode 2 temperature error) 2 Reserved Read only Undefined (reserved for remote thermal diode 2 fault) 3 Reserved Read only Undefined 4 GPI input Read/write A 1 disables the corresponding interrupt status bit for the INT output. 5 Remote temperature error Read/write A 1 disables the corresponding interrupt status bit for the INT output. 6 THERM input Read/write A 1 disables the corresponding interrupt status bit for the INT output. 7 Remote diode fault Read/write A 1 disables the corresponding interrupt status bit for the INT output. |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |