50 / 77 page ![]() ADT7467 Rev. 3 | Page 50 of 77 | www.onsemi.com Enhanced Acoustics Register 1 (0x62) Bit 7 (MIN3) = 0, PWM3 is off (0% PWM duty cycle) when the temperature is below TMIN − THYST. Bit 7 (MIN3) = 1, PWM3 runs at PWM3 minimum duty cycle below TMIN − THYST. Bit 6 (MIN2) = 0, PWM2 is off (0% PWM duty cycle) when the temperature is below TMIN − THYST. Bit 6 (MIN2) = 1, PWM2 runs at PWM2 minimum duty cycle below TMIN − THYST. Bit 5 (MIN1) = 0, PWM1 is off (0% PWM duty cycle) when the temperature is below TMIN − THYST. Bit 5 (MIN1) = 1, PWM1 runs at PWM1 minimum duty cycle below TMIN − THYST. STEP 9: OPERATING POINTS FOR TEMPERATURE CHANNELS The operating point for each temperature channel is the optimal temperature for that thermal zone. The hotter each zone is allowed to be, the more quiet the system, because the fans are not required to run as fast. The ADT7467 increases or decreases fan speeds as necessary to maintain the operating point temperature, allowing for system-to-system variations and eliminating the need to design for the worst case. If a sensible operating point value is chosen, any TMIN value can be selected in the system characterization. If the TMIN value is too low, the fans run sooner than required and the temperature is below the operating point. In response, the ADT7467 increases TMIN to keep the fans off longer and to allow the temperature zone to approach the operating point. Likewise, too high a TMIN value causes the operating point to be exceeded, and, in turn, the ADT7467 reduces TMIN to turn the fans on sooner to cool the system. Programming Operating Point Registers There are three operating point registers, one for each tempera- ture channel. These 8-bit registers allow the operating point temperatures to be programmed with 1°C resolution. Operating Point Registers Register 0x33, Remote 1 operating point = 0xA4 (100°C default) Register 0x34, local temperature operating point = 0xA4 (100°C default) Register 0x35, Remote 2 operating point = 0xA4 (100°C default) OPERATING POINT REAR CHASSIS FRONT CHASSIS CPU FAN SINK LOCAL = VRM TEMP PWM1 PWM2 TACH1 TACH2 TACH3 PWM3 REMOTE 1 = AMBIENT TEMP REMOTE 2 = CPU TEMP MUX THERMAL CALIBRATION 0% TMIN TRANGE THERMAL CALIBRATION 100% 0% TMIN TRANGE THERMAL CALIBRATION 100% 0% TMIN TRANGE TACHOMETER 1 MEASUREMENT PWM CONFIG PWM MIN RAMP CONTROL (ACOUSTIC ENHANCEMENT) PWM GENERATOR TACHOMETER 2 MEASUREMENT PWM CONFIG PWM MIN RAMP CONTROL (ACOUSTIC ENHANCEMENT) PWM GENERATOR TACHOMETER 3 AND 4 MEASUREMENT PWM CONFIG PWM MIN RAMP CONTROL (ACOUSTIC ENHANCEMENT) PWM GENERATOR 100% Figure 69. Operating Point Value Dynamically Adjusts Automatic Fan Control Settings |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |