55 / 77 page ![]() ADT7467 Rev. 3 | Page 55 of 77 | www.onsemi.com putting the ADT7467 into manual mode and changing the PWM output from 0% to 100% PWM duty cycle. The PWM output takes 35 sec to reach 100% when a ramp rate of 1 time slot is selected. Figure 76 shows remote temperature plotted against PWM duty cycle for enhanced acoustics mode. The ramp rate is set to 48, which corresponds to the fastest ramp rate. Assume that a new temperature reading is available every 115 ms. With these settings, it takes approximately 0.76 sec to go from 33% duty cycle to 100% duty cycle (full speed). Even though the temperature increases very rapidly, the fan ramps up to full speed gradually. 140 00.76 120 100 80 60 40 20 0 120 100 80 60 40 20 0 RTEMP (°C) PWM DUTY CYCLE (%) TIME (s) Figure 76. Enhanced Acoustics Mode with Ramp Rate = 48 Figure 77 shows how a ramp rate of 8 affects the control loop. The overall response of the fan is slower than it is with a ramp rate of 48. Because the ramp rate is reduced, it takes longer for the fan to achieve full running speed. In this case, it takes approximately 4.4 sec for the fan to reach full speed. TIME (s) 120 0 4.4 140 120 100 80 60 40 0 20 100 80 60 40 20 0 RTEMP (°C) PWM DUTY CYCLE (%) Figure 77. Enhanced Acoustics Mode with Ramp Rate = 8 Figure 78 shows the PWM output response for a ramp rate of 2. With these conditions, the fan takes about 17.6 sec to reach full running speed. TIME (s) 140 0 17.6 120 100 80 60 40 20 0 120 100 80 60 40 20 0 RTEMP (°C) PWM DUTY CYCLE (%) Figure 78. Enhanced Acoustics Mode with Ramp Rate = 2 Figure 79 shows how the control loop reacts to temperature with the slowest ramp rate. The ramp rate is set to 1; all other control parameters are the same as they are for Figure 76 through Figure 78. With the slowest ramp rate selected, it takes 35 sec for the fan to reach full speed. TIME (s) 0 35 120 100 80 60 40 20 0 140 120 100 80 60 40 20 0 PWM DUTY CYCLE (%) RTEMP (°C) Figure 79. Enhanced Acoustics Mode with Ramp Rate = 1 As Figure 76 to Figure 79 show, the rate at which the fan reacts to a temperature change is dependent on the ramp rate selected in the enhanced acoustics registers. The higher the ramp rate, the faster the fan reaches the newly calculated fan speed. |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |