| Datenblatt-Suchmaschine für elektronische Bauteile |
|
LP55231 Datenblatt(PDF) 45 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
LP55231 Datenblatt(HTML) 45 Page - Texas Instruments |
|
45 / 53 page ![]() LP55231 www.ti.com SNOSCR5 – MARCH 2013 Name Value (d) Description 0 = variable A target variable 0 - 2 1 = variable B 2 = variable C 0 = local variable A 1 = local variable B variable 1 (ii) 0 - 3 2 = global variable C 3 = register address 3CH variable, or register address 42H value. 0 = local variable A 1 = local variable B variable 2 (ii) 0 - 3 2 = global variable C 3 = register address 3CH variable, or register address 42H value. SUB SUB Operator either subtracts 8-bit value from the current value of the target variable, or subtracts the value of the variable 2 (A, B, C or D) from the value of the variable 1 (A, B, C or D) and stores the result in the register of target variable (A, B or C). Variables overflow from 0 to 255. Name Value (d) Description 8-bit value (i) 0 - 255 The value to be added. 0 = variable A target variable 0 - 2 1 = variable B 2 = variable C 0 = local variable A 1 = local variable B variable 1 (ii) 0 - 3 2 = global variable C 3 = register address 3CH variable, or register address 42H value. 0 = local variable A 1 = local variable B variable 2 (ii) 0 - 3 2 = global variable C 3 = register address 3CH variable, or register address 42H value. Automatic Power-Save Mode Automatic power-save mode is enabled when POWERSAVE_EN bit in register address 36H is “1". Almost all analog blocks are powered down in power-save if an external clock signal is used. Only the charge-pump protection circuits remain active. However, if the internal clock has been selected, only charge pump and LED drivers are disabled during the power save; the digital part of the LED controller needs to stay active. In both cases the charge pump enters the weak 1x mode. In this mode the charge pump utilizes a passive current limited keep-alive switch, which keeps the output voltage at the battery level. During the program execution LP55231 can enter power save if there is no PWM activity in any of the LED driver outputs. To prevent short power-save sequences during program execution, LP55231 has an instruction look-ahead filter. During program execution engine 1, engine 2 and engine 3 instructions are constantly analyzed, and if there are time intervals of more than 50 ms in length with no PWM activity on LED driver outputs, the device will enter power save. In power-save mode program execution continues uninterrupted. When an instruction that requires PWM activity is executed, a fast internal-startup sequence will be started automatically. Copyright © 2013, Texas Instruments Incorporated Submit Documentation Feedback 45 Product Folder Links: LP55231 |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |