| Datenblatt-Suchmaschine für elektronische Bauteile |
|
EMC1413 Datenblatt(PDF) 31 Page - SMSC Corporation |
|
|
|||||||||||||||||||||||||||||
EMC1413 Datenblatt(HTML) 31 Page - SMSC Corporation |
|
31 / 52 page ![]() Multiple Channel 1°C Temperature Sensors with Beta Compensation Datasheet SMSC EMC1413 / EMC1414 31 Revision 1.41 (02-23-12) DATASHEET Bit 4 - RECD1 - Disables the Resistance Error Correction (REC) for External Diode 1. ‘0’ (default) - REC is enabled for External Diode 1. ‘1’ - REC is disabled for External Diode 1. Bit 3 - RECD2 - Disables the Resistance Error Correction (REC) for External Diode 2 and External Diode 3. ‘0’ (default) - REC is enabled for External Diode 2 and External Diode 3. ‘1’ - REC is disabled for External Diode 2 and External Diode 3. Bit 2 - RANGE - Configures the measurement range and data format of the temperature channels. ‘0’ (default) - The temperature measurement range is 0°C to +127.875°C and the data format is binary. ‘1’ -The temperature measurement range is -64°C to +191.875°C and the data format is offset binary (see Table 6.2). Bit 1 - DAVG_DIS - Disables the dynamic averaging feature on all temperature channels. ‘0’ (default) - The dynamic averaging feature is enabled. All temperature channels will be converted with an averaging factor that is based on the conversion rate as shown in Table 6.1. ‘1’ - The dynamic averaging feature is disabled. All temperature channels will be converted with a maximum averaging factor of 1x (equivalent to 11-bit conversion). For higher conversion rates, this averaging factor will be reduced as shown in Table 6.1. Bit 0 - APDD (EMC1414 only) - Disables the anti-parallel diode operation. Beta Compensation is disabled on External Diode 2 and 3 regardless of APDD setting. In addition, External Diode 2 Beta Configuration register will be ignored. ‘0’ (default) - Anti-parallel diode mode is enabled. Two external diodes will be measured on the DP2 and DN2 pins. ‘1’ - Anti-parallel diode mode is disabled. Only one external diode will be measured on the DP2 and DN2 pins. 7.5 Conversion Rate Register The Conversion Rate Register controls how often the temperature measurement channels are updated and compared against the limits. This register is fully accessible at either address. Bits 3-0 - CONV[3:0] - Determines the conversion rate as shown in Table 7.6. Table 7.5 Conversion Rate Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 04h R/W Conversion Rate - - - - CONV[3:0] 06h (4/sec) 0Ah Table 7.6 Conversion Rate CONV[3:0] CONVERSIONS / SECOND HEX 3 2 1 0 0h 0 0 0 0 1 / 16 1h 0 0 0 1 1 / 8 |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |