37 / 52 page ![]() Multiple Channel 1°C Temperature Sensors with Beta Compensation Datasheet SMSC EMC1413 / EMC1414 37 Revision 1.41 (02-23-12) DATASHEET Bits 6-4 - CTHRM[2:0] - Determines the number of consecutive measurements that must exceed the corresponding Therm Limit before the THERM pin is asserted. All temperature channels use this value to set the respective counters. The consecutive Therm counter is incremented whenever any measurement exceed the corresponding Therm Limit. If the temperature drops below the Therm Limit, the counter is reset. If a number of consecutive measurements above the Therm Limit occurs, the THERM pin is asserted low. Once the THERM pin has been asserted, the consecutive therm counter will not reset until the corresponding temperature drops below the Therm Limit minus the Therm Hysteresis value. The bits are decoded as shown in Table 7.14. The default setting is 4 consecutive out of limit conversions. Bits 3-1 - CALRT[2:0] - Determine the number of consecutive measurements that must have an out of limit condition or diode fault before the ALERT pin is asserted. All temperature channels use this value to set the respective counters. The bits are decoded as shown in Table 7.14. The default setting is 1 consecutive out of limit conversion. 7.13 Beta Configuration Registers These registers are used to set the Beta Compensation factor that is used for the external diode channels. Bit 3 - ENABLEX - Enables the Beta Compensation factor auto-detection function. The ENABLE2 control is disabled for the EMC1414; beta compensation cannot be enabled for External Diode 2 or 3. ‘0’ - The Beta Compensation Factor auto-detection circuitry is disabled. ‘1’ - The Beta Compensation factor auto-detection circuitry is enabled. At the beginning of every conversion, the optimal Beta Compensation factor setting will be determined and applied. The BETAX[2:0] bits will be automatically updated to indicate the current setting. This is the default for Table 7.14 Consecutive Alert / Therm Settings 21 0 NUMBER OF CONSECUTIVE OUT OF LIMIT MEASUREMENTS 00 0 1 (default for CALRT[2:0]) 00 1 2 01 1 3 11 1 4 (default for CTHRM[2:0]) Table 7.15 Beta Configuration Registers ADDR. R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 25h R/W External Diode 1 Beta Configuration - - - - ENABLE1 BETA1[2:0] 08h 26h R/W External Diode 2 Beta Configuration - - - - ENABLE2 BETA2[2:0] 08h for EMC1413 and 07h for EMC1414 |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |