| Datenblatt-Suchmaschine für elektronische Bauteile |
|
AM79C975VCW Datenblatt(PDF) 259 Page - Advanced Micro Devices |
|
|
|||||||||||||||||||||||||||||
AM79C975VCW Datenblatt(HTML) 259 Page - Advanced Micro Devices |
|
259 / 304 page ![]() Am79C973/Am79C975 259 P R E L I M INARY Default: 00 Read only, write has no effect. This two bit field indicates the current power state of the Am79C975 controller. The defini- tion of the field values is given below: 00b - D0 01b - D1 10b - D2 11b - D3 5 RESERVED Default: 0Read as ZERO only Reserved bits. For future use only 4 PVALID Default: 0Read only, write has no effect. When PVALID is set to a 1, it indicates that there is an EEPROM connected to the Am79C975 controller and that the read opera- tion of the EEPROM has passed the checksum verification. All registers that are loaded from the EEPROM contain data read from the EE- PROM. PVALID is cleared by H_RESET. 3RXON Default: 0 Read only, write has no effect. When RXON is set to a 1, it indicates that the receive function for normal operation is en- abled. Note that the reception of management frames via the SMIU is only controlled by the MRX_ENABLE bit in the Receive Status regis- ter, but not of the state of RXON. RXON is cleared by H_RESET. 2TXON Default: 0 Read only, write has no effect. When TXON is set to a 1, it indicates that the transmit function for normal operation is en- abled. Note that the transmission of manage- ment frames via the SMIU is always active, independent of the state of TXON. TXON is cleared by H_RESET. 1STOP Default: 1 Read only, write has no effect. When STOP is set to a 1, it indicates that all bus master activity of the Am79C975 controller is disabled. STOP is set to 1 by H_RESET. 0STRT Default: 0 Read only, write has no effect. When STRT is set to a 1, it indicates that the Am79C975 controller is initialized for normal mode of operation and that the device is setup to perform bus master activity. STRT is cleared by H_RESET. MIU Transceiver Status (MReg Address 30) This register is a shadow register of some bits in the transceiver status register. Bit No. Name and Description 7:4 RESERVED Default: 0000Read as ZERO only Reserved bits. For future use only 3LINK Default: 0 Read only, write has no effect. When LINK is set to 1, it indicates that the physical layer interface of the Am79C975 con- troller is in Link Pass state. A value of 0 indi- cates a Link Fail state. 2 DUPLEX Default: 0 Read only, write has no effect. When DULPEX is set to 1, it indicates that the physical layer interface is operating in full-du- plex mode. A value of 0 indicates half-duplex mode. 1 SPEED Default: 0 Read only, write has no effect. When SPEED is set to 1, it indicates that the physical layer interface is operating at 100 Mbps. A value of 0 indicates a speed of 10 Mbps. 0 AUTONEG_DONEDefault: 0Read only, write has no effect. When AUTONEG_DONE is set to 1, it indi- cates that the autonegotiation process of the physical layer interface with the other end of the network cable has completed. Control and Status Registers The following registers control the transmission and re- ception of management frames and provide status of the operation. |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |