| Datenblatt-Suchmaschine für elektronische Bauteile |
|
SM5902AF Datenblatt(PDF) 27 Page - Nippon Precision Circuits Inc |
|
|
|||||||||||||||||||||||||||||
SM5902AF Datenblatt(HTML) 27 Page - Nippon Precision Circuits Inc |
|
27 / 40 page ![]() NIPPON PRECISION CIRCUITS-27 SM5902AF - DRAM initialization refresh A 15-cycle RAS-only refresh is carried out for DRAM initialization under the following conditions. When MSON changes from 0 to 1 using command 80H. When from MSON=1, MSRDEN=0 and MSWREN=0 states only MSWREN changes to 1. In this case, encode sequence immediately starts and initial data is written (at 2fs rate input) after a delay of 0.7ms. - Refresh during Shock-proof mode operation In this IC, a data access operation to any address also serves as a data refresh. Accordingly, there are no specific refresh cycles other than the initial- ization refresh cycle (described above). This has the resulting effect of saving on DRAM power dissipation. A data access to DRAM can occur in an encode sequence write operation or in a decode sequence read operation. Write sequence write operation stops during a connect operation whereas a read sequence read operation always continues while data is output to the D/A. The refresh rate for each DRAM during decode sequence is shown in the table below. The decode sequence, set by MSON=1 and MSR- DEN=1, operates when valid data is in DRAM (when MSEMP=0). - When MSON=0, DRAM is not refreshed because no data is being accessed. Although MSON=1, DRAM is not refreshed if ENCOD=0 and DECOD=0 (both encode and decode sequence are stopped). DRAM refresh Table 2. Decode sequence refresh rate DRAMs used (same for 1 or 2 DRAMs) Data compression mode 1M (256K ×4 bits) 4M (1M ×4 bits) 16M(4M ×4 bits) 4 bit 5.44 ms 10.88 ms 21.77ms 5 bit 4.35 ms 8.71 ms 17.42ms 6 bit 3.63 ms 7.26 ms 14.52ms Full bit 1.36 ms 2.72 ms 5.81ms Encode sequence temporary stop - When RAM becomes full, MSWREN is set LOW using the 80H command and encode sequence stops. (For details of the stop conditions, refer to the description of the ENCOD flag.) - Then, if MSWREN is set HIGH without issuing a compare-connect start command, the encode sequence re-starts. At this time, new input data is written not to VWA, but to WA. In this way, the data already written to the region between VWA and WA is not lost. - But if the MSWREN is set HIGH (80H command) after using the compare-connect start command even only once, data is written to VWA. If data is input before comparison and conformance is detected, the same operation as direct-connect mode takes place when the command is issued. After comparison and conformance are detected, no operation is performed because the encode sequence has already been started. However, make sure that the other bit settings within the same 80H command are valid. |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |