37 / 60 page ![]() 11.0 MICROWIRE/PLUS (Continued) 11.1.2 MICROWIRE/PLUS Slave Mode Operation In the MICROWIRE/PLUS Slave mode of operation the SK clock is generated by an external source. Setting the MSEL bit in the CNTRL register enables the SO and SK functions onto the G Port. The SK pin must be selected as an input and the SO pin is selected as an output pin by setting and re- setting the appropriate bits in the Port G configuration regis- ter. Table 10 summarizes the settings required to enter the Slave mode of operation. This table assumes that the control flag MSEL is set. TABLE 10. MICROWIRE/PLUS Mode Settings G4 (SO) G5 (SK) G4 G5 Operation Config. Bit Config. Bit Fun. Fun. 1 1 SO Int. MICROWIRE/PLUS SK Master 0 1 TRI- Int. MICROWIRE/PLUS STATE SK Master 1 0 SO Ext. MICROWIRE/PLUS SK Slave 0 0 TRI- Ext. MICROWIRE/PLUS STATE SK Slave The user must set the BUSY flag immediately upon entering the Slave mode. This ensures that all data bits sent by the Master is shifted properly. After eight clock pulses the BUSY flag is clear, the shift clock is stopped, and the sequence may be repeated. 10.1.3 Alternate SK Phase Operation and SK Idle Polarity The device allows either the normal SK clock or an alternate phase SK clock to shift data in and out of the SIO register. In both the modes the SK idle polarity can be either high or low. The polarity is selected by bit 5 of Port G data register. In the normal mode data is shifted in on the rising edge of the SK clock and the data is shifted out on the falling edge of the SK clock. The SIO register is shifted on each falling edge of the SK clock. In the alternate SK phase operation, data is shifted in on the falling edge of the SK clock and shifted out on the rising edge of the SK clock. Bit 6 of Port G configuration reg- ister selects the SK edge. A control flag, SKSEL, allows either the normal SK clock or the alternate SK clock to be selected. Resetting SKSEL causes the MICROWIRE/PLUS logic to be clocked from the normal SK signal. Setting the SKSEL flag selects the alter- nate SK clock. The SKSEL is mapped into the G6 configura- tion bit. The SKSEL flag will power up in the reset condition, selecting the normal SK signal. TABLE 11. MICROWIRE/PLUS Shift Clock Polarity and Sample/Shift Phase Port G SO Clocked Out On: SI Sampled On: SK Idle Phase SK Phase G6 (SKSEL) G5 Config. Bit Data Bit Normal 0 0 SK Falling Edge SK Rising Edge Low Alternate 1 0 SK Rising Edge SK Falling Edge Low Alternate 0 1 SK Rising Edge SK Falling Edge High Normal 1 1 SK Falling Edge SK Rising Edge High DS012838-33 FIGURE 25. MICROWIRE/PLUS SPI Mode Interface Timing, Normal SK Mode, SK Idle Phase being Low DS012838-34 FIGURE 26. MICROWIRE/PLUS SPI Mode Interface Timing, Alternate SK Mode, SK Idle Phase being Low www.national.com 37 |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |