14 / 23 page ![]() Design Section (Continued) This is the fraction of the switching period that the switch is on. The switch is off for the remainder of the period. This fraction is expressed as: D’ = 1−D The LM3477/A has limits for the maximum and minimum duty cycle (see ELECTRICAL CHARACHTERISTICS). The maximum duty cycle of 93% (typical) will limit how low the input voltage may drop while maintaining a regulated output voltage (the dropout voltage). In situations where a very low dropout voltage is required, it is necessary to include V D,VQ and V SN losses in the maximum duty cycle calculation. Voltage drops in the inductor will lower the dropout voltage as well. The minimum duty cycle of the LM3477/A corresponds to the minimum on time, or blank out time (see ELECTRICAL CHARACHTERISTICS). D MIN =TMIN* fs This will not limit how high the input voltage can rise, how- ever the LM3477/A will operate in hysteretic mode once the operating duty cycle decreases to the minimum duty cycle. Programming the Current Limit/Hysteretic Threshold DEFINITIONS: Current Limit: The current limit is the point at which the LM3477/A begins to limit the peak switch current. The cur- rent limit in the LM3477/A varies with duty cycle, which is a function of the V IN −VOUT differential. Hysteric Threshold: Hysteretic threshold is the current at which the LM3477/A enters the hysteretic mode of operation (see OVER VOLTAGE PROTECTION section). The hyster- etic threshold is with respect to the peak switch current. Setting Current Limit and Hysteretic Threshold The adjustable current limit of the LM3477/A is set by the sense resistor R SN. The voltage across RSN is compared to an internal control voltage V C. The onset of current limiting is when V SEN(peak) equals VC(max),orVCL.VSEN is defined here as the differential voltage from the V IN pin to the ISEN pin. V CL decreases as the duty cycle increases, as shown in Figure 7. Therefore, it is important to know both V SEN(peak) and V CL(min) at the maximum operating duty cycle, or lowest V IN condition. V CL(MIN) =VCL(0)(MIN) −D(MAX) (VCL(0)(MIN) −VCL(100)(MIN)) where D MAX is the duty cycle at the lowest VIN condition. To avoid current limit, V SEN(peak) < VCL(MIN) Therefore, 200033K3 FIGURE 7. Current Limit and Hysteretic Threshold vs Duty Cycle www.national.com 14 |
|
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |