CY28400
Document #: 38-07591 Rev. **
Page 10 of 14
Absolute Maximum Conditions
Parameter
Description
Condition
Min.
Max.
Unit
VDD
Core Supply Voltage
–0.5
4.6
V
VDD_A
Analog Supply Voltage
–0.5
4.6
V
VIN
Input Voltage
Relative to VSS
–0.5
VDD + 0.5 VDC
TS
Temperature, Storage
Non-functional
–65
150
°C
TA
Temperature, Operating Ambient
Functional
0
70
°C
TJ
Temperature, Junction
Functional
–
150
°C
ØJC
Dissipation, Junction to Case
Mil-Spec 883E Method 1012.1
–
TBD
°C/W
ØJA
Dissipation, Junction to Ambient
JEDEC (JESD 51)
–
TBD
°C/W
ESDHBM
ESD Protection (Human Body Model)
MIL-STD-883, Method 3015
2000
–
V
UL-94
Flammability Rating
At 1/8 in.
V–0
MSL
Moisture Sensitivity Level
1
Multiple Supplies: The Voltage on any input or I/O pin cannot exceed the power pin during power-up. Power supply sequencing
is NOT required.
DC Electrical Specifications
Parameter
Description
Condition
Min.
Max.
Unit
VDD_A, VDD 3.3V Operating Voltage
3.3 ± 5%
3.135
3.465
V
VILI2C
Input Low Voltage
SDATA, SCLK
–
1.0
V
VIHI2C
Input High Voltage
SDATA, SCLK
2.2
–
V
VIL
3.3V Input Low Voltage
VSS – 0.5
0.8
V
VIH
3.3V Input High Voltage
2.0
VDD + 0.5
V
IIL
Input Low Leakage Current
except internal pull-up resistors, 0 < VIN < VDD
–5
µA
IIH
Input High Leakage Current
except internal pull-down resistors, 0 < VIN < VDD
5
µA
IOZ
High-impedance Output Current
–10
10
µA
CIN
Input Pin Capacitance
2
5
pF
COUT
Output Pin Capacitance
3
6
pF
LIN
Pin Inductance
–
7
nH
IDD3.3V
Dynamic Supply Current
At max. load and 100 MHz per Figure 8
–215
mA
IPD3.3V
Power-down Supply Current
PD asserted, Outputs driven
–
40
mA
IPD3.3V
Power-down Supply Current
PD asserted, Outputs Three-stated
–
5
mA
AC Electrical Specification
Parameter
Description
Condition
Min.
Max.
Unit
DIF at 0.7V
TDC
DIFT and DIFC Duty Cycle
Measured at crossing point VOX
45
55
%
TSKEW
Any DIFT/C to DIFT/C Clock Skew, SSC Measured at crossing point VOX
–
150
ps
TPERIOD
Average Period
Measured at crossing point VOX at 100 MHz
9.9970
10.0533
ns
TCCJ
DIFT/C Cycle to Cycle Jitter
Measured at crossing point VOX
–50
ps
TR / TF
DIFT and DIFC Rise and Fall Times
Measured from VOL = 0.175 to VOH = 0.525V
175
700
ps
TRFM
Rise/Fall Matching
Determined as a fraction of 2*(TR – TF)/(TR + TF)–
20
%
∆TR
Rise Time Variation
–
125
ps
∆TF
Fall Time Variation
–
125
ps
VHIGH
Voltage High
Measured SE
660
850
mv
VLOW
Voltage Low
Measured SE
–150
–
mv