Back Button D10DPFPG Datasheet HTML 8Page - Banner Engineering Corp. D10DPFPG Datasheet HTML 9Page - Banner Engineering Corp. D10DPFPG Datasheet HTML 10Page - Banner Engineering Corp. D10DPFPG Datasheet HTML 11Page - Banner Engineering Corp. D10DPFPG Datasheet HTML 12Page - Banner Engineering Corp. D10DPFPG Datasheet HTML 13Page - Banner Engineering Corp. D10DPFPG Datasheet HTML 14Page - Banner Engineering Corp. D10DPFPG Datasheet HTML 15Page - Banner Engineering Corp. D10DPFPG Datasheet HTML 16Page - Banner Engineering Corp.  
Zoom Inzoom in Zoom Outzoom out
 13 / 16 page
background image
Method
Action
Result
Remote Input
a. Double-pulse the remote line to toggle between
selections.
b. Single-pulse the remote line to save selection
and advance to "Factory Default."
T
T
T
T
3. Return the sensor to the factory default settings, if desired.
Method
Action
Result
Push Button
a. Click Dynamic (+) to toggle between selections.
b. Click Static (-) to save selection and advance to
"Display Orientation."
Returns to factory default factory
settings
Factory Default Settings Not Selected:
Display shows "Fd n"
Factory Default Settings Selected:
Display shows "Fd Y"
Remote Input
a. Double-pulse the remote line to toggle between
selections.
b. Single-pulse the remote line to save selection
and advance to "Display Orientation."
T
T
T
T
4. Change the display orientation, if desired.
Method
Action
Result
Push Button
a. Click Dynamic (+) to toggle between selections.
b. Click Static (-) to return to RUN mode.
Inverts display to read "upside-
down"
Normal
For example: 1234
Inverted
For example:
NOTE: Icons do
not invert.
Remote Input
a. Double-pulse the remote line to toggle between
selections.
b. Single-pulse the remote line to return to RUN
mode.
T
T
T
T
Push Button Lockout
•
Prevents unwanted adjustments or tampering of the push buttons
•
Push buttons can be enabled or disabled only from the remote line and only during normal RUN mode
Method
Action
Result
Push Button22
Not available with push-button programming.
Push buttons Disabled
•
Display flashes "loc"
•
Padlock icon appears
•
Sensor remains in RUN mode
Push Buttons Enabled
•
Display flashes "uloc"
•
Padlock icon disappears
•
Sensor remains in RUN mode
Remote Input23
From RUN mode, quad-pulse the remote line to
toggle between selections.
T
T
T
T
T
T
T
22 0.04 seconds ≤ "Click" ≤ 0.8 seconds
23 0.04 seconds ≤ T ≤ 0.8 seconds
D10 Expert™– Dual Discrete Outputs
P/N 64154 Rev. G
www.bannerengineering.com - Tel: +1-763-544-3164
13



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16


Datenblatt Download

Go To PDF Page


Link URL



War ALLDATASHEET hilfreich?  [ DONATE ] 

Über Alldatasheet   |   Werbung   |   Kontakt   |   Privatsphäre und Datenschutz   |   Link zum Datenblatt    |   Linktausch   |   Hersteller
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com