| Datenblatt-Suchmaschine für elektronische Bauteile |
|
MP4680 Datenblatt(PDF) 8 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
MP4680 Datenblatt(HTML) 8 Page - NXP Semiconductors |
|
8 / 28 page ![]() 1996 Oct 25 8 Philips Semiconductors Product specification Video processor with automatic cut-off and white level control TDA4680 AUTO-INCREMENT The auto-increment format enables quick slave receiver initialization by one transmission, when the I2C-bus control bit BREN = 0 (see control register bits of Table 1). If BREN = 1 auto-increment is not possible. If the auto-increment format is selected, the MAD byte is followed by a SAD byte and by the data bytes of consecutive sub-addresses (Fig.6). All sub-addresses from 00H to 0FH are automatically incremented, the sub-address counter wraps round from 0FH to 00H. Reserved sub-addresses 0BH, 0EH and 0FH are treated as legal but have no effect. Sub-addresses outside the range 00H and 0FH are not acknowledged by the device and neither auto-increment nor any other internal operation takes place (for versions V1 to V5 sub-addresses outside the range 00H and 0FH are acknowledged but neither auto-increment nor any other internal operation takes place). Sub-addresses are stored in the TDA4680 to address the following parameters and functions (see Table 1): • Brightness adjust • Saturation adjust • Contrast adjust • Hue control voltage • RGB gain adjust • RGB reference voltage levels • Peak drive limiting adjust • Control register functions. The data bytes D7 to D0 (see Table 1) provide the data of the parameters and functions for video processing. CONTROL REGISTER 1 VBWx (Vertical Blanking Window): x = 0, 1 or 2. VBWx selects the vertical blanking interval and positions the measurement lines for cut-off and white level control. The actual lines in the vertical blanking interval after the start of the vertical pulses selected as measurement lines for cut-off and white level control are shown in Table 2. The standards marked with (*) are for progressive line scan at double line frequency (2fL), i.e. approximately 31 kHz. NMEN (NTSC Matrix Enable): 0 = PAL/SECAM matrix 1 = NTSC matrix. WPEN (White Pulse Enable): 0 = white measuring pulse disabled 1 = white measuring pulse enabled. BREN (Buffer Register Enable): 0 = new data is executed as soon as it is received 1 = data is stored in buffer registers and is transferred to the data registers during the next vertical blanking interval. The I2C-bus transceiver does not accept any new data until this data is transferred into the data registers. DELOF (Delay Off) delays the leading edge of clamping pulses: 0 = delay enabled 1 = delay disabled. SC5 (SandCastle 5 V): 0 = 3-level sandcastle pulse 1 = 2-level (5 V) sandcastle pulse. CONTROL REGISTER 2 FSON2 (Fast Switch 2 ON) FSDIS2 (Fast Switch 2 Disable) FSON1 (Fast Switch 1 ON) FSDIS1 (Fast Switch 1 Disable) The RGB input signals are selected by FSON2 and FSON1 or FSW2 and FSW1: • FSON2 has priority over FSON1 • FSW2 has priority over FSW1 • FSDIS1 and FSDIS2 disable FSW1 and FSW2 (see Table 3). BCOF (Black level Control Off): 0 = automatic cut-off control enabled 1 = automatic cut-off control disabled; RGB outputs are clamped to fixed DC levels. FSBL (Full Screen Black Level): 0 = normal mode 1 = full screen black level (cut-off measurement level during full field). FSWL (Full Screen White Level): 0 = normal mode 1 = full screen white level (white measurement level during full field). |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |