| Datenblatt-Suchmaschine für elektronische Bauteile |
|
BMP581 Datenblatt(PDF) 64 Page - Bosch Sensortec GmbH |
|
|
|||||||||||||||||||||||||||||
BMP581 Datenblatt(HTML) 64 Page - Bosch Sensortec GmbH |
|
64 / 75 page ![]() Bosch Sensortec | BST-BMP581-DS004-11 64 | 75 © Bosch Sensortec GmbH 2023 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, Document number: BST-BMP581-DS004-11 as well as in the event of applications for industrial property rights 7.33 Register (0x36) Over-sampling rate (OSR) configuration Bit 7 6 5 4 3 2 1 0 Read/Write R R/W R/W R/W R/W R/W R/W R/W Reset Value 0 0 0 0 0 0 0 0 Content reserved_7 press_en osr_p osr_t osr_t:(bit offset: 0) OSR_T selection Value Description 0b000 (0x0) oversampling rate = 1x 0b001 (0x1) oversampling rate = 2x 0b010 (0x2) oversampling rate = 4x 0b011 (0x3) oversampling rate = 8x 0b100 (0x4) oversampling rate = 16x 0b101 (0x5) oversampling rate = 32x 0b110 (0x6) oversampling rate = 64x 0b111 (0x7) oversampling rate = 128x osr_p:(bit offset: 3) OSR_P selection Value Description 0b000 (0x0) oversampling rate = 1x 0b001 (0x1) oversampling rate = 2x 0b010 (0x2) oversampling rate = 4x 0b011 (0x3) oversampling rate = 8x 0b100 (0x4) oversampling rate = 16x 0b101 (0x5) oversampling rate = 32x 0b110 (0x6) oversampling rate = 64x 0b111 (0x7) oversampling rate = 128x press_en:(bit offset: 6) If set, enables sensor pressure measurements. Otherwise temperature only measurements is done. reserved_7:(bit offset: 7) reserved Note: the configured ODR might be invalid in combination with OSR configuration. This is observable with the ODR_-CONFIG.flag odr_is_valid. If configured ODR/OSR settings are invalid, default OSR settings will be used. The effective OSR settings for P/T can be read from osr_t_eff and osr_p_eff 7.34 Register (0x37) Output data rate (ODR) configuration Bit 7 6 5 4 3 2 1 0 Read/Write R/W R/W R/W R/W R/W R/W R/W R/W Reset Value 0 1 1 1 0 0 0 0 Content deep_dis odr pwr_mode pwr_mode:(bit offset: 0) Power mode configuration The user can request a dedicated power mode by writing this field. A read returns the actual mode the device is in. Note: This bit is cleared again upon transition from FORCED to STANDBY mode. |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |