| Datenblatt-Suchmaschine für elektronische Bauteile |
|
BMP581 Datenblatt(PDF) 44 Page - Bosch Sensortec GmbH |
|
|
|||||||||||||||||||||||||||||
BMP581 Datenblatt(HTML) 44 Page - Bosch Sensortec GmbH |
|
44 / 75 page ![]() Bosch Sensortec | BST-BMP581-DS004-11 44 | 75 © Bosch Sensortec GmbH 2023 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, Document number: BST-BMP581-DS004-11 as well as in the event of applications for industrial property rights 5.7.3 Common Command Codes (CCC) Supported I3C command control codes (CCCs) are listed in Table 27. Table 27: List of I3C CCCs CCC Code CCC Type CCC name Description BMP581 Supported 0x00 Broadcast ENEC Enable events Y 0x01 Broadcast DISEC Disable events Y 0x02 Broadcast ENTAS0 Enter active state 0 N 0x03 Broadcast ENTAS1 Enter active state 1 N 0x04 Broadcast ENTAS2 Enter active state 2 N 0x05 Broadcast ENTAS3 Enter active state 3 N 0x06 Broadcast RSTDAA Reset dynamic address Y 0x07 Broadcast ENTDAA Enter dynamic address assignment Y 0x08 Broadcast DEFSLVS Define list of slaves N 0x09 Broadcast SETMWL Set max write length N 0x0A Broadcast SETMRL Set max read length N 0x0B Broadcast ENTTM Enter test mode N 0x20 Broadcast ENTHDR0 Enter HDR mode 0 N 0x21 Broadcast ENTHDR1 Enter HDR mode 1 N 0x22 Broadcast ENTHDR2 Enter HDR mode 2 N 0x23 Broadcast ENTHDR3 Enter HDR mode 3 N 0x24 Broadcast ENTHDR4 Enter HDR mode 4 N 0x25 Broadcast ENTHDR5 Enter HDR mode 5 N 0x26 Broadcast ENTHDR6 Enter HDR mode 6 N 0x27 Broadcast ENTHDR7 Enter HDR mode 7 N 0x28 Broadcast SETXTIME Exchange timing information Y 0x80 Direct ENEC Enable events Y 0x81 Direct DISEC Disable events Y 0x82 Direct ENTAS0 Enter active state 0 N 0x83 Direct ENTAS1 Enter active state 1 N 0x84 Direct ENTAS2 Enter active state 2 N 0x85 Direct ENTAS3 Enter active state 3 N 0x86 Direct RSTDAA Reset dynamic address Y 0x87 Direct SETDASA Set dynamic address from static addressa Y 0x88 Direct SETNEWDA Set new dynamic address Y 0x89 Direct SETMWL Set max write length N 0x8A Direct SETMRL Set max read length N 0x8B Direct GETMWL Get max write length N 0x8C Direct GETMRL Get max read length N 0x8D Direct GETPID Get provisional ID Y 0x8E Direct GETBCR Get bus characteristics register Y 0x8F Direct GETDCR Get device characteristics register Y 0x90 Direct GETSTATUS Get device status Y 0x91 Direct GETACCMST Get accept mastership N 0x93 Direct SETBRGTGT Get bridge status N 0x94 Direct GETMXDS Get max data speed N 0x95 Direct GETHDRCAP Get HDR capability Y 0x98 Direct SETXTIME Exchange timing information Y 0x99 Direct GETXTIME Get timing information Y a. CCC SETDASA can be used once to assign the dynamic address. If the address shall be changed without resetting or power-cycling the device, CCC SETNEWDA must be used. |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |