| Datenblatt-Suchmaschine für elektronische Bauteile |
|
L99PM72PXP Datenblatt(PDF) 18 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L99PM72PXP Datenblatt(HTML) 18 Page - STMicroelectronics |
|
18 / 128 page ![]() Detailed description L99PM72PXP 18/128 Doc ID 023553 Rev 3 Moreover, in Flash Mode the DO-output is a test output and cannot be used for device communication. All other device features in Flash Mode are available as in Active Mode. The CAN-Receiver is enabled in CAN Flash Mode by default; the CAN Transmitter has to be enabled by setting the CAN_ACT bit to ‘1’. A transition from Flash Modes to V1_standby or Vbat_standby is not possible. The modes can be entered by applying an external voltage at the respective pin: ● VTxDL > Vflash (CAN Flash Mode) ● VTxDC > Vflash (LIN Flash Mode) At exit from Flash Modes (VTxD <Vflash) no NReset pulse is generated and the watchdog starts with a long open window. Note: Setting both TxDL and TxDC to high voltage levels (> Vflash) is not allowed Communication at the respective TxD pin is not possible 2.2.3 SW-Debug Mode To allow software debugging, the watchdog can be deactivated by setting CR34: WDEN = 0. Write access to this bit is only possible during CAN Flash Mode in order to prevent accidental deactivation of the watchdog. After setting the WDEN bit the CAN Flash Mode can be left (VTxDL <VFlash) and the Watchdog remains deactivated (see Figure 8) In SW-Debug Mode, the full device functionality is available. Figure 8. Sequence to enter and exit SW Debug Mode 2.2.4 V1_standby mode The transition from Active Mode to V1_standby mode is controlled by SPI. To supply the micro controller in a low power mode, the voltage regulator 1 (V1) remains active. In order to reduce the current consumption, the regulator goes in low current mode as soon as the supply current of the microcontroller goes below the ICMP current threshold. At this transition, the L99PM72PXP also deactivates the internal watchdog. Relay outputs, LIN and CAN Transmitters are switched off in V1_standby Mode. High side outputs and the V2 regulator remain in the configuration programmed prior to the standby command. |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |