| Datenblatt-Suchmaschine für elektronische Bauteile |
|
TMP512 Datenblatt(PDF) 32 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TMP512 Datenblatt(HTML) 32 Page - Texas Instruments |
|
32 / 62 page ![]() TMP512 TMP513 SBOS491A – JUNE 2010 – REVISED MAY 2011 www.ti.com REGISTER INFORMATION The TMP512/13 uses a bank of registers for holding the write command. Therefore, a 4 μs delay is configuration settings, measurement results, required between the completion of a write to a given maximum/minimum limits, and status information. register and a subsequent read of that register Table 3 summarizes the TMP512/13 registers. (without changing the pointer) when using SCL Register contents are updated 4 μs after completion of frequencies in excess of 1MHz. Table 3. Summary of Register Set POINTER ADDRESS POWER-ON RESET HEX REGISTER NAME FUNCTION BINARY HEX TYPE(1) All-register reset, settings for bus voltage range, PGA Gain, Bus 00 Configuration Register 1 ADC resolution/averaging, Shunt ADC resolution/averaging, 00111001 10011111 399F R/W one-shot, Operation Mode. Settings for Temperature Continuous conversion, Remote Configuration Register 2 01 Channels enable, Local Channel enable, resistance correction 1011111110000x00 BF80/BF84 R/W TMP512 enable, Conversion rate bits, and GPIO mode bit and readback. Settings for Temperature Continuous conversion, Remote Configuration Register 2 01 Channels enable, Local Channel enable, resistance correction 11111111 10000x00 FF80/FF84 R/W TMP513 enable, Conversion rate bits, and GPIO mode bit and readback. 02 Status Register Contains the alert and conversion ready flags. 00000000 00000000 0000 R SMBus Alert Mask/Enable 03 Contains masks to enable/disable the alert functions. 00000000 00000000 0000 R/W Control Register 04 Shunt Voltage Result Shunt voltage measurement result. 00000000 00000000 0000 R 05 Bus Voltage Result Bus voltage measurement result. 00000000 00000000 0000 R 06 Power Result Power measurement result. 00000000 00000000 0000 R Contains the value of the current flowing through the shunt 07 Shunt Current Result(2) 00000000 00000000 0000 R resistor. 08 Local Temperature Result Contains local temperature measurement result. 00000000 00000000 0000 R Remote Temperature 09 Contains remote temperature measurement result. 00000000 00000000 0000 R Result 1 Remote Temperature 0A Contains remote temperature measurement result. 00000000 00000000 0000 R Result 2 Remote Temperature 0B(3) Contains remote temperature measurement result. 00000000 00000000 0000 R Result 3 Shunt Voltage Positive 0C Contains the positive limit for Shunt Voltage. 00000000 00000000 0000 R/W Limit Shunt Voltage Negative 0D Contains the negative limit for Shunt Voltage. 00000000 00000000 0000 R/W Limit 0E Bus Voltage Positive Limit Contains the positive limit for Bus Voltage. 00000000 00000000 0000 R/W 0F Bus Voltage Negative Limit Contains the negative limit for Bus Voltage. 00000000 00000000 0000 R/W 10 Power Limit Contains the positive limit for Power. 00000000 00000000 0000 R/W 11 Local Temperature Limit Contains positive limit for local temperature. 00101010 10000000 2A80 R/W (1) Type: R = Read-Only, R/W = Read/Write. (2) Current Register defaults to '0' because the Calibration Register defaults to '0', yielding a zero current value until the Calibration Register is programmed. (3) For TMP513 only. 32 Copyright © 2010–2011, Texas Instruments Incorporated |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |