| Datenblatt-Suchmaschine für elektronische Bauteile |
|
TMP512 Datenblatt(PDF) 14 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TMP512 Datenblatt(HTML) 14 Page - Texas Instruments |
|
14 / 62 page ![]() TMP512 TMP513 SBOS491A – JUNE 2010 – REVISED MAY 2011 www.ti.com SERIES RESISTANCE CANCELLATION Local Temperature Result Register and the Remote Temperature Result Registers. Note that byte 1 is the Series resistance in an application circuit that typically most significant byte, followed by byte 2, the least results from printed circuit board (PCB) trace significant byte. The first 13 bits are used to indicate resistance and remote line length is automatically temperature. The least significant byte does not have cancelled by the TMP512/13, preventing what would to be read if that information is not needed. The data otherwise result in a temperature offset. A total of up format for temperature is summarized in Table 10. to 3k Ω of series line resistance is cancelled by the One LSB equals 0.0625 °C. Negative numbers are TMP512/13, eliminating the need for additional represented in binary twos complement format. characterization and temperature offset correction. Following power-up or reset, the Temperature See the Remote Temperature Error vs Series Register will read 0 °C until the first conversion is Resistance typical characteristic curves (Figure 15 ) complete. Unused bits in the Temperature Register for details on the effects of series resistance and always read '0'. power-supply voltage on sensed remote temperature error. REGISTER INFORMATION DIFFERENTIAL INPUT CAPACITANCE The TMP512/13 contain multiple registers for holding configuration information, temperature and voltage The TMP512/13 can tolerate differential input measurement results, and status information. These capacitance of up to 2200pF with minimal change in registers are described in Table 3. temperature error. The effect of capacitance on sensed remote temperature error is illustrated in POINTER REGISTER Figure 16, Remote Temperature Error vs Differential Capacitance. See the Filtering section for suggested The 8-bit Pointer Register is used to address a given component values where filtering unwanted coupled data register. The Pointer Register identifies which of signals is needed. the data registers should respond to a read or write command on the two-wire bus. This register is set TEMPERATURE MEASUREMENT DATA with every write command. A write command must be issued to set the proper value in the Pointer Register Temperature measurement data may be taken over before executing a read command. Table 3 describes an operating range of –40°C to +125°C for both local the pointer address of the TMP512/13 registers. The and remote locations. power-on reset (POR) value of the Pointer Register is 00h (0000 0000b). The Temperature Register of the TMP512/13 is configured as a 13-bit, read-only register that stores the output of the most recent conversion. Two bytes must be read to obtain data, and are described in the 14 Copyright © 2010–2011, Texas Instruments Incorporated |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |