| Datenblatt-Suchmaschine für elektronische Bauteile |
|
SCA3000-D01 Datenblatt(PDF) 21 Page - VTI technologies |
|
|
|||||||||||||||||||||||||||||
SCA3000-D01 Datenblatt(HTML) 21 Page - VTI technologies |
|
21 / 43 page ![]() SCA3000 Series VTI Technologies Oy 21/ 43 www.vti.fi Doc.Nr. 8257300A.07 Rev.A.07 Address value: 00010 Register name: MD_CTRL, Motion Detector control (Indirect access via CTRL_SEL) Bits Initial Value Name Description Note 7:6 Reserved 5 0 REQ_Z 1 – Require trigger on Z-channel 0 – Not required 4 0 REQ_X 1 – Require trigger on X-channel 0 – Not required 3 0 REQ_Y 1 – Require trigger on Y-channel 0 – Not required Bits 5:3 can be used to build logical AND operation between channels. Example: X and Y = Require X and Y, ignore Z → 00 011 011 2 1 EN_Z 1 – Enable trigger on Z-channel 0 – Not required 1 1 EN_X 1 – Enable trigger on X-channel 0 – Not required 0 1 EN_Y 1 – Enable trigger on Y-channel 0 – Not required Bits 2:0 can be used to build logical OR operation between channels. Example: X or Y = Disable Z → 00 000 011 Address value: 00011 Register name: MD_Y_TH, Motion Detector Y-threshold (Indirect access via CTRL_SEL) Bits Initial Value Name Description 7:0 10h or 08h Y_TH Threshold for Y-acceleration change when MD is used. Address value: 00100 Register name: MD_X_TH, Motion Detector X-threshold (Indirect access via CTRL_SEL) Bits Initial Value Name Description 7:0 10h or 08h X_TH Threshold for X-acceleration change when MD is used. Address value: 00101 Register name: MD_Z_TH, Motion Detector Z-threshold (Indirect access via CTRL_SEL) Bits Initial Value Name Description 7:0 10h or 08h Z_TH Threshold for Z-acceleration change when MD is used. Initial values for registers MD_X_TH, MD_Y_TH and MD_Z_TH vary with SCA3000 product types. Initial value is: • 10h for SCA3000-D01, SCA3000-D02, SCA3000-E01 and SCA3000-E02 • 08h for SCA3000-E04 and SCA3000-E05 The bit level descriptions for registers MD_X_TH, MD_Y_TH and MD_Z_TH are presented in, Table 11 ...Table 14 below. The threshold levels are in unsigned format and they are absolute values for the acceleration that triggers the motion detector interrupt. Values presented below are typical threshold values and they are not factory calibrated. |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |