73 / 151 page ![]() FEDL7344C/E/J-04 ML7344C/E/J 73/151 NOTE: *1 Digital filter delay is “AD conversion time * 8”. AD conversion time can be slected by ADC_CLK_SEL ([ADC_CLK_SET: B1 0x08(4)]). Reset value is 1.73MHz and AD conversion time is 18.5μs. (2) Continuous mode Continuous mode continues CCA untill terminated by the host MCU. CCA continuous mode will be executed when RX_ON is issued while CCA_EN(CCA_CTRL: B0 0x39(4)])=0b1, CCA_CPU_EN(CCA_CTRL: B0 0x39(5)])=0b1 and CCA_IDLE_EN(CCA_CTRL: B0 0x39(6)])=0b0 are set. Like normal mode, CCA judgement is determined by average ED value in [ED_RSLT: B0 0x3A] register and CCA threshold defined by [CCA_LVL: B0 0x37] register. IF average ED value exceeds the CCA threshold value, it is considered as “BUSY”. And CCA_RSLT[1:0]([CCA_CTRL: B0 0x39(1-0)]) = 0b01 is set. If average ED value is smaller than CCA threshold value and maintains IDLE detection period which is defined by IDLE_WAIT[9:0] of the [IDLE_WAIT_L: B0 0x3B], [IDLE_WAIT_H: B0 0x3C] registers, it is considered as “IDLE”. And CCA_RSLT[1:0] =0b00 is set. For details operation of CCA_IDLE_WAIT[9:0], please refer to ”IDLE detection for long time period”. If an ED value exceeds the value defined by [CCA_IGNORE_LVL: B0 0x36] register, a given ED value is included in the averaging target of ED value calculation, IDLE judgement is not performed. In this case if average ED value exceeds CCA threshold level, it is considered as “BUSY” and CCA_RSLT[1:0] indicates 0b01. If average ED value is smaller than CCA threshold level, IDLE judgement is not determined. And CCA_RSLT[1:0] indicates 0b11. For details operation of ED value execeeding [CCA_IGNORE_LVL: B0 0x36] register, please refer to ”IDLE determination exclusion under strong signal input”. Continuous mode does not stop when “BUSY” or “IDLE” is detected. CCA operation continues until 0b1 is set to CCA_STOP([CCA_CTRL: B0 0x39(7)]). Result is updated every time ED value is acquired. CCA completion interrup (INT[18] group3) will not be generated. |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |