| Datenblatt-Suchmaschine für elektronische Bauteile |
|
E39-R1 Datenblatt(PDF) 82 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E39-R1 Datenblatt(HTML) 82 Page - Omron Electronics LLC |
|
82 / 100 page ![]() Fiber Amplifiers, Communications Unit and Accessories E3X-HD Fiber Amplifiers, Communications Unit and Accessories E3X-HD 82 Threaded Cylindrical Flat Sleeved Small Spot High Power Retro- reflective Limited- reflective Narrow view BGS Chemical- resistant, Oil-resistant Bending Heat- resistant Area Detection Liquid-level Vacuum FPD, Semi, Solar Installation Information 83 Installation Information Threaded Cylindrical Flat Sleeved Small Spot High Power Retro- reflective Limited- reflective Narrow view BGS Chemical- resistant, Oil-resistant Bending Heat- resistant Area Detection Liquid-level Vacuum FPD, Semi, Solar 82 83 I/O Circuit Diagrams NPN Output PNP Output Nomenclature Operating Procedures (1) Detect for Workpiece Presence/Absence (2) Enhance Durability of the Fiber Head against Dust and Stain • 2-point Tuning Incident light level setting: The incident level in Step 1 is adjusted to "0". Threshold setting: The value is set to approx. 7% of the incident light level of 1. If the incident light level of 1 is smaller during long distance detection, the minimum value by which an output is correctly turned ON will be set. Incident light level setting: Adjust the max. incident light level on Step 1 as the power tuning level. Threshold setting: Set to the middle between max. and min. incident light levels on Step 1. Incident light level setting: The Step 2 incident level is adjusted to half the power tuning level. Threshold setting:Set to the same value as the Step 2 incident level. (3) Adjust for Moving Workpiece without Stopping Line • Full Auto Tuning (4) Determine Workpiece Position • Position Tuning 1. 2. Incident light level setting: The larger incident level of the Step 1 and 2 values is adjusted to the power tuning level. Threshold setting:Set to the middle between the Step 1 and 2 incident light levels. Through-beam: Workpiece is present Reflective: Workpiece is absent The red digital display changes [1pnt] →[ full] The red digital display changes [2pnt] → [p,s]. Workpiece Workpiece Basic Settings Workpiece Setting is Completed Setting is Completed Setting is Completed Setting is Completed Setting is Completed Step 1 and Step 2 can be reversed. Output switching Smart Tuning [Easy Sensitivity Setting] • Percentage Tuning • Smart Tuning Error Incident light level setting: The Step 2 incident light level is adjusted to the power tuning level. Threshold setting:Set to the value obtained by [Incident Level at Step 2 × Percentage Tuning Level + Incident Level at Step 2]. (5) Detect Transparent or Small Workpiece (Set Threshold by incident light level percentage) 1. Turn ON Percentage Tuning in SET mode. 2. Error / Display / Cause Remedy Error Origin Tuning Type 2-point Tuning Full Auto Tuning Positioning Tuning All Tuning other than Maximum Sensitivity Tuning • Change the detection function mode to a slower response time mode. • Reduce the distance between the light emitting and light receiving surfaces. (Through-beam) • Place the Fiber Head closer to the sensing object. (Reflective) • Enhance the power tuning level. • Use a thin-diameter fiber. • Widen the emitter and receiver distance (Through-beam) • Distance the Fiber Head from the sensing object(Reflective) • Decrease the power tuning level. • Reduce the distance between the light emitting and light receiving surfaces. (Through-beam) • Place the Fiber Head closer to the sensing object. (Reflective) The light level difference between Points 1 and 2 are extremely small. Incident light level is too high. Incident light level is too low. Near Error Over Error Low Error Minute Adjustment of Threshold Level 1. No Smart Tuning other than Power Tuning can be used if Percentage Tuning is set. The adjustment range of smart tuning is approx. 20 to 1/100 times. When selecting giga mode as detection function, the range will be approx. 2 to 1/100 times due to the large initial value. Hold the key for high-speed level adjustment. per st The threshold level becomes higher. The threshold level becomes lower. Refer to "Detailed Settings" to change the power tuning level. Refer to "Detailed Settings". L/D indicators Models Operation mode Timing chart Output circuit E3X-HD11 E3X-HD6 E3X-HD14 Light-ON Dark-ON L/D indicators Models Operation mode Timing chart Output circuit E3X-HD41 E3X-HD8 E3X-HD44 Light-ON Dark-ON lit. D lit. L lit. D lit. L Workpiece 1pnt st p,5 st Load Brown Control output Black Blue OUT indicator (orange) Photoelectric Sensor main circuit 12 to 24 VDC Display OUT indicator (orange) Output transistor Load (e.g., relay) Incident light No incident light Lit Not lit ON OFF Set Reset (Between brown and black leads) OUT indicator (orange) Output transistor Load (e.g., relay) (Between brown and black leads) Incident light No incident light Lit Not lit ON OFF Set Reset OUT indicator (orange) Output transistor Load (e.g., relay) Incident light No incident light Lit Not lit ON OFF Set Reset (Between blue and black leads) OUT indicator (orange) Output transistor Load (e.g., relay) (Between blue and black leads) Incident light No incident light Lit Not lit ON OFF Set Reset Control output Brown Black Blue 12 to 24 VDC OUT indicator (orange) Display Photoelectric Sensor main circuit Load Note: Timing Charts for Timer Settings (T: Set Time) Incident light No incident light ON OFF ON OFF ON delay OFF delay One-shot Light-ON Dark-ON Incident light No incident light ON OFF ON OFF Light-ON Dark-ON Incident light No incident light ON OFF ON OFF Light-ON Dark-ON T T T T T T [L/D Indicator] Indicates the setting status: Light-ON (L) or Dark-ON (D). [DPC Indicator] Turns ON when Dynamic Power Control is effective. [ L/D Button] Use to switch between Light-ON (L) and Dark-ON (D). [OUT Indicator] Turns ON when the output is ON. [ST Indicator] Turns ON when Smart Tuning is in progress. Automatically sets the emitter power and set values. Threshold Level Green digital display Incident Level Red digital display [+ −UP/DOWN Button] Used to fine-tune the threshold or change set values. [ MODE Button] Use to switch between Detection Mode and Setting Mode. [ TUNE Button] Press button. Through-beam: Set to “Dark ON" to turn the output ON with a workpiece in the detection area. [L/D Indicator] turns ON. Reflective: Set to “Light ON" to turn the output ON with a workpiece in the detection area. [L/D Indicator] turns ON. 1. L/D D L Press button with a workpiece in the detection area. 1. TUNE Press button again without a workpiece in the detection area. 2. TUNE • Maximum Sensitivity Tuning Hold button for 3 seconds or longer with/without workpiece as shown below. Release the button when [ st full] is displayed. 1. TUNE Hold for 3 seconds or longer Hold for 3 seconds or longer Hold for 7 seconds or longer Hold the button without the presence of a workpiece, and pass the workpiece through while [1pnt] → [ full] → [ aut,] is displayed in red digital. (Keep holding the button while the workpiece passes through, and hold 7 seconds or longer until [ aut,] is displayed in red digital. After the workpiece passes through, release your finger from the button.) 1. TUNE TUNE TUNE Press button without a workpiece in the area. TUNE Place the workpiece at the desired position and hold button. TUNE Press button without a workpiece in the area. TUNE UP/DOWN Press button to adjust the threshold level. • M8 Connector Pin Arrangement Note: Pin 2 is not used. 1 2 4 3 1 4 3 • M8 Connector Pin Arrangement Note: Pin 2 is not used. 1 2 4 3 1 4 3 Plug (Sensor I/O Connector) Note: Pin 2 is not used. Wire color Connection pin Application Brown 1 Power supply (+V) White 2 --- Blue 3 Power supply (0 V) Black 4 Output 2 4 1 3 1 2 3 4 Brown White Blue Black Wire color Terminal number XS3F-M421-402-A XS3F-M421-405-A XS3F-M422-402-A XS3F-M422-405-A |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |