| Datenblatt-Suchmaschine für elektronische Bauteile |
|
E39-R1 Datenblatt(PDF) 93 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E39-R1 Datenblatt(HTML) 93 Page - Omron Electronics LLC |
|
93 / 100 page ![]() Safety Precautions Safety Precautions 92 Threaded Cylindrical Flat Sleeved Small Spot High Power Retro- reflective Limited- reflective Narrow view BGS Chemical- resistant, Oil-resistant Bending Heat- resistant Area Detection Liquid-level Vacuum FPD, Semi, Solar Installation Information 93 Installation Information Threaded Cylindrical Flat Sleeved Small Spot High Power Retro- reflective Limited- reflective Narrow view BGS Chemical- resistant, Oil-resistant Bending Heat- resistant Area Detection Liquid-level Vacuum FPD, Semi, Solar 92 93 Fiber Unit Connection Side Hook 1 2 DIN Track 2 Tighten the screw while pressing the End Plate. 3 4 Protective Cover Fiber Unit 1 3 Single Core Multi Core 2 4 Lock Lever Lock Release Protective Sticker Power Supply Connecting Terminal Protective Cap Precautions for Safe Use Fiber Amplifier Unit For common precautions, refer to www.ia.omron.com Mounting the Fiber Amplifier Units Mounting Fiber Units This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. The following precautions must be observed to ensure safe operation of the product. Doing so may cause damage or fire. Precautions for Correct Use (1) Be sure to mount the unit to the DIN track until it clicks. (2) When using Amplifier Units with Wire-saving Connectors, attach the protective stickers (provided with E3X-CN-series Connectors) on the unused power pins to prevent electrical shock and short circuiting. When using Amplifier Units with Connectors for Communications Units, attach the protective caps (provided with Sensor Communications Unit). Mounting Amplifier Units in Group (Wire-saving Connector Type Models) 1. Mount the Fiber Amplifier units one at a time onto the DIN track and push them until they click. 2. Slide the Fiber Amplifier units in the direction 2. 3. Use End Plates (PFP-M: separately sold) at the both ends of the grouped Fiber Amplifier units to prevent them from separating due to vibration or other cause. 4. Tighten the screw on the End Plates using a driver. (3) <E3NX-FA series> The length for the cable extension must be 30 m or less (or less than 10 m for S-mark certified models). Be sure to use a cable of at least 0.3 mm2 for extension. The power voltage must be 24 to 30 V when connecting amplifier units with extension cable and wire-saving connector. <E3X-HD series> The length for the cable extension must be 100 m or less. Be sure to use a cable of at least 0.3 mm2 for extension. (4) Do not apply the forces on the cord exceeding the following limits: Pull: 40N; torque: 0.1N·m; pressure: 20N; bending: 29.4N (5) Do not apply excessive force such as tension, compression or torsion to the Amplifier Unit with the Fiber Unit fixed to the Amplifier Unit. (6) Always keep the protective cover in place when using the Amplifier Unit. Not doing so may cause malfunction. (7) It may take time until the received light intensity and measured value become stable immediately after the power is turned on depending on use environment. (8) The product is ready to operate 200 ms after the power supply is turned ON. (9) The Mobile Console E3X-MC11, E3X-MC11-SV2 and E3X-MC11-S cannot be connected. (10) Mutual interference prevention on the E3NX-FA Series does not function among the E3X-HD, E3X-DA-S, E3X-DA-N, E3X-SD, or E3X-NA Fiber Amplifier Units. Mutual interference prevention on the E3X-HD Series does not function among the E3NX-FA, E3X-DA-N, E3X-SD, or E3X-NA Fiber Amplifier Units. Mutual interference prevention on the E3X-HD Series does function among the E3X-DA-S and E3X-MDA Fiber Amplifier Units. (11) If the unit receives excessive sensor light, the mutual interference prevention function may not work properly, resulting in malfunction of the unit. In such case, increase the threshold. (12) The E3NW-ECT Sensor Communications Unit can be used with the E3NX-FA0, but the E3X-DRT21-S, E3X-CRT, and E3X-ECT Sensor Communications Units cannot be used. The E3X-CRT and E3X-ECT Sensor Communications Unit can be used with the E3X-HD0, but the E3X-DRT21-S and E3NW-ECT Sensor Communications Units cannot be used. (13) If you notice an abnormal condition such as a strange odor, extreme heating of the unit, or smoke immediately stop using the product, turn off the power, and consult your dealer. (14) Do not use thinner, benzine, acetone, and lamp oil for cleaning. Do not use the product with voltage in excess of the rated voltage. Excess voltage may result in malfunction or fire. Never use the product with AC power supply. Otherwise, explosion may result. • Under environments such as vibration, use an end plates even with a single Fiber Amplifier Unit. • The maximum numbers of connectable Amplifier Units are given in the following table. • If Units are to be connected, the ambient temperature will change with the number of Units that are connected. Check the Ratings and Characteristics specifications. • Always turn OFF the power before connecting or disconnecting Units. * The mutual interference prevention function cannot be used if the detection mode is set to super-high-speed mode (SHS). 1. Open the protective cover. 2. Raise the lock lever. 3. Insert the Fiber Unit in the fiber unit hole to the bottom. 4. Return the lock lever to the original position and fix the Fiber Unit. • When mounting a coaxial reflective Fiber Unit, insert the single-core Fiber Unit to the upper hole (Emitter side) and the multi-core Fiber Unit to the lower hole (Receiver side). The cables for the Single-core Fiber Units (Emitters) have identification marks. Refer to the dimensions diagrams for details. • When removing the Fiber Unit, follow the above steps in reverse order. To maintain the characteristics of the Fiber Unit, make sure the lock is released before removing the Fiber Unit. Maximum number of mutual interference prevention Maximum number of interconnected E3X-HD series standard models* (E3X-HD11/HD41/HD6/HD8) E3X-HD0 With E3X-ECT 16 10 30 16 10 10 With E3X-CRT Thin Fiber Attachment (E39-F9) Loosely tighten. Fiber Cutter E39-F4 Thin-diameter Fiber Unit Hole × 2 Standard Fiber Unit Hole (dia. 2.2 mm) × 3 About 0.5 mm Insertion direction Cut a thin fiber as follows. For standard fibers, insert to the desired cutting position and cut. Adjust the fiber to the desired length and fully tighten. (1) (2) Insert the Fiber Unit into E39-F4 and cut it. (3) Finished state. (Correctly cut end) (4) Amplifier Unit with Wire-saving Connector Amplifier Unit with Connector for Communications Unit E3NX-FA series* 30 10 Warning (1) Do not install the product in the following locations. • Locations subject to direct sunlight • Locations subject to condensation due to high humidity • Locations subject to corrosive gas • Locations subject to vibration or mechanical shocks exceeding the rated values • Locations subject to exposure to water, oil, chemicals • Locations subject to stream • Locations subjected to strong magnetic field or electric field (2) Do not use the product in environments subject to flammable or explosive gases. (3) Do not use the product in any atmosphere or environment that exceeds the ratings. (4) To secure the safety of operation and maintenance, do not install the product close to high-voltage devices and power devices. (5) High-Voltage lines and power lines must be wired separately from this product. Wiring them together or placing them in the same duct may cause induction, resulting in malfunction or damage. (6) Do not apply load exceeding the ratings. Otherwise, damage or fire may result. (7) Do not short the load. Otherwise, damage or fire may result. (8) Connect the load correctly. (9) Do not miswire such as the polarity of the power supply. (10) Do not use the product if the case is damaged. (11) Burn injury may occur. The product surface temperature rises depending on application conditions, such as the ambient temperature and the power supply voltage. Attention must be paid during operation or cleaning. (12) When setting the Sensor, be sure to check safety, such as by stopping the equipment. (13) Be sure to turn off the power supply before connecting or disconnecting wires. (14) Do not attempt to disassemble, repair, or modify the product Unit in any way. (15) When disposing of the product, treat it as industrial waste. (16) Do not use the Sensor in water, rain, or outdoors. 1. Let the hook on the Amplifier Unit's Fiber Unit connection side catch the track and push the unit until it clicks. Mounting on DIN Track 1. Push the unit in the direction 1. 2. Lift it up in the direction 2. Removing from DIN Track Refer to “I/O Circuit Diagrams” or check the side of the unit for wire color and role indications. Mount Fiber Unit Use Fiber Cutter The fiber is shipped loosely tightened as shown in the figure at the right Note: The insertion direction into the Fiber Amplifier Unit is shown in the above figure. 25 mm 10 mm 11.7 mm |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |