| Datenblatt-Suchmaschine für elektronische Bauteile |
|
E39-R1 Datenblatt(PDF) 44 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E39-R1 Datenblatt(HTML) 44 Page - Omron Electronics LLC |
|
44 / 100 page ![]() Environmental Immunity Heat-resistant Environmental Immunity Heat-resistant 44 44 Threaded Cylindrical Flat Sleeved Small Spot High Power Retro- reflective Limited- reflective Narrow view BGS Chemical- resistant, Oil-resistant Bending Heat- resistant Area Detection Liquid-level Vacuum FPD, Semi, Solar Installation Information 45 45 Installation Information Threaded Cylindrical Flat Sleeved Small Spot High Power Retro- reflective Limited- reflective Narrow view BGS Chemical- resistant, Oil-resistant Bending Heat- resistant Area Detection Liquid-level Vacuum FPD, Semi, Solar Through-beam → This page Reflective → 46 page E32-T51R 2M (Free Cutting) E32-T81R-S 2M (No Cutting) 45-A 45-C E32-T51 2M (Free Cutting) E32-T61-S 2M (No Cutting) 45-B 45-D 15 2.85 dia. 1 Sensing surface 1.5 dia. 17 2,000 2.2 dia. Opposite side 7, thickness 2.4 (Nickel-plated brass) Washer (Nickel-plated iron) M4×0.7 (Nickel-plated brass) M2.6×0.45 Sensing surface 1 dia. Opposite side 7, thickness 2.4 (Nickel-plated brass) Washer (Nickel-plated iron) 2.2 dia. 3 14 2,000 M4×0.7 (SUS303) 3.2 Note: The maximum allowable temperatures for sections A and B are 350°C and 110°C, respectively. The section inserted into the Amplifier Unit (indicated by *) must be maintained within the Amplifier Unit's operating temperature range. 20 3 4 dia. 10 2,000 25 (B) * A 4 dia. Fluororesin tube 2.8 dia. (SUS304) M2.6×0.45 2.2 dia. M4×0.7 (SUS303) Sensing surface 1 dia. Opposite side 7, thickness 2.4 (SUS304) Washer (SUS) 30 Sensing surface 0.7 dia. 20 3 4 dia. 10 2,000 30 (B) * A 4 dia. Fluororesin tube 2 dia. Protective tube M2.6×0.45 2.2 dia. (75) M4×0.7 (SUS303) Opposite side 7, thickness 2.4 (SUS304) Washer (SUS) Note: The maximum allowable temperatures for sections A and B are 200°C and 110°C, respectively. The section inserted into the Amplifier Unit (indicated by *) must be maintained within the Amplifier Unit's operating temperature range. 2,520 900 2,400 840 4,000*5 1,500 1,500 540 M4 20 30 M4 20 30 M4 17 M4 14 Heat- resistant temperature E32-T51R 2M 100°C *1 150℃ *2 200℃ *3 350℃ *4 70℃ Flexible, R2 R35 R10 R25 0.7 dia. (5 μm dia./ 2 μm dia.) 1 dia. (0.1 dia./ 0.03 dia.) 1 dia. (5 μm dia./ 2 μm dia.) 1.5 dia. (0.1 dia./ 0.03 dia.) E32-T51 2M 1,200 225 45-A 45-B E32-T81R-S 2M 45-C E32-T61-S 2M 45-D Standard Fiber Units can be used. --- Appearance (mm) Bending radius of cable Sensing distance (mm) Optical axis diameter (minimum sensing object) Models 45 Page Dimensions No. ST : SHS: 2,250 400 ST : SHS: 820 140 ST : SHS: IP50 IP67 IP67 IP67 1,350 240 ST : SHS: 1,680 600 1,600 560 800 225 2,800 1,000 E3X-HD ST : SHS: 1,500 400 ST : SHS: 550 140 ST : SHS: 1,000 360 900 240 ST : SHS: E3NX-FA Other modes HS GIGA Other modes HS GIGA • Wide product variety for temperatures from 100 to 350°C. Select the model according to heat-resistant temperature. Specifications Dimensions Through-beam Fiber Units *1 For continuous operation, use the Fiber Unit between −40 to 90°C. *2 For continuous operation, use the Fiber Unit between −40 to 130°C. *3 The heat-resistant rating is not the same for all parts of the Fiber Unit. Refer to the dimensions diagrams for details. *4 The ambient operating temperature for the E32-T61-S 2M is −60 to 350°C. *5 The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm. Through-beam Fiber Units (Set of 2) Installation Information → 60 Page Long-distance Sensing Applications A separate Lens Unit can be attached to extend the sensing distance. → 28 page The following mode names and response times apply to the modes given in the Sensing distance column. [E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs) [E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and SHS: Super-high-speed mode (30 μs) The values for the minimum sensing object are reference values that indicate values obtained in standard mode with the sensing distance and sensitivity set to the optimum values. The first value is for the E3X-HD and the second value is for the E3NX-FA. Note 1. 2. - Reference Information for Model Selection - |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |