| Datenblatt-Suchmaschine für elektronische Bauteile |
|
E39-R Datenblatt(PDF) 63 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E39-R Datenblatt(HTML) 63 Page - Omron Electronics LLC |
|
63 / 100 page ![]() Fiber Amplifiers, Communications Unit and Accessories Main Features Fiber Amplifiers, Communications Unit and Accessories Main Features 62 Threaded Cylindrical Flat Sleeved Small Spot High Power Retro- reflective Limited- reflective Narrow view BGS Chemical- resistant, Oil-resistant Bending Heat- resistant Area Detection Liquid-level Vacuum FPD, Semi, Solar Installation Information 63 Installation Information Threaded Cylindrical Flat Sleeved Small Spot High Power Retro- reflective Limited- reflective Narrow view BGS Chemical- resistant, Oil-resistant Bending Heat- resistant Area Detection Liquid-level Vacuum FPD, Semi, Solar 62 63 Advanced Smart Tuning Achieve Easy Detection in Many Applications Just press the button once with a workpiece and once without a workpiece to automatically set the optimum incident level and threshold. Consistent settings are achieved for all users with this ultra-easy procedure. The Sensor Communications Unit with a master function and the Distributed Sensor Units with slave functions enable N-Smart Sensors communication over open networks. E3NX-FA Series Smart Fiber Amplifier Units A Smart Fiber Amplifier Unit with Ultra-stable Detection and Ultra-easy Setup E3X-ECT / E3X-CRT Fiber Amplifier Unit Accessories Sensor Communications Units for E3X-HD Sensor Communications Units for CompoNet and EtherCAT 64 Page 64 Page 78 Page 65, 79 Page Optimum Light Intensity Adjustment from Transparent Objects to Black Workpieces The incident level is optimized to enable stable detection even for saturated or insufficient incident levels. Greatly Reduced Machine Manufacturing Costs There is no need to change the current distributed installation to introduce a network without increasing costs. Greatly Reduced Machine Commissioning Time All of the settings can be made at the same time from a Touch Panel. Greatly Improved Machine Productivity Realtime monitoring lets you perform maintenance before malfunctions occur. Improvements in the sensing distance and minimum sensing object have increased the range of application for stable detection. NEW E3NW Series Sensor Communications Units for E3NX-FA E3X-HD Series Smart Fiber Amplifier Units Affordable Amplifier Units with Simple Operation and Stable Detection Capabilities 78 Page Advanced Basic Performance Expanded Application Response Capabilities <Fiber Amplifier Unit Comparison> TUNE The Next-generation E3NW Sensor Network Units Revolutionize On-site Sensing Press the button once with a workpiece and once without a workpiece TUNE Automatic Setting of Optimum Values 5000 9999 ST Set to the intermediate value between the incident levels with and without a workpiece. Incident level adjustment with and without a workpiece 1.5 Times the Sensing Distance* 1/10th the Minimum Sensing Object* 6 m 0.3 µm dia. *Compared to E3X-HD. For E32-LT11 Fiber Unit with a fiber length of 3.5 m Typical example of actual measurements with E32-D11R Fiber Unit. ×1/2000 ×20 ×1 Excessive Incident Level Incident light reduced. Light Intensity Adjustment Range of 40,000 Times Incident light increased. NEW Controller Sensor Communications Units Master Distributed Sensor Units Slaves Open Network Network between Units Fiber Amplifier Unit specifications Output External input Response time Ordering Information Page listings Ratings and Specifications Dimensions Sensing distance (Giga-power mode) E32-D11R E32-T11R Minimum sensing object Communications method (Sensor Communications Unit model) Applicable Sensors E32-T11R Sensor Communications Unit application 1 or 2 outputs (depending on the model) Supported or not supported (depending on the model) 30 μs (32 μs)/250 μs/1 ms/16 ms (Default: 250 μs) 3,000 mm 1,260 mm 2 μm dia. EtherCAT (E3NW-ECT) CompoNet (E3NW-CRT) CC-Link (E3NW-CCL) 68 Page 66 Page 64 Page Fiber Sensor (E3NX-FA0) Laser Sensors (E3NC-LA0, E3NC-SA0) Contact-Type Sensor (E9NC-TA0) * E3NX-FA Series 1 output Not supported 50 μs (55 μs)/250 μs/1 ms/16 ms (Default: 250 μs) 2,000 mm 840 mm 5 μm dia. EtherCAT (E3X-ECT) CompoNet (E3X-CRT) 80 Page 80 Page 78 Page Fiber Sensor (E3X-HD0) Fiber Sensor (E3X-MDA0) Laser Photoelectric Sensor (E3C-LDA0) Proximity Sensor (E2C-EDA0) E3X-HD Series Threshold + Incident Level * E3NW-CRT Sensor Communications Units (CompoNet) cannot be used. |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |