269 / 304 page ![]() Am79C973/Am79C975 269 P R E L I M INARY MII Receive Interface The MII receive clock is also generated by the external PHY and is sent to the Am79C973/Am79C975 control- ler on the RX_CLK input pin. The clock will be the same frequency as the TX_CLK but will be out of phase and can run at 25 MHz or 2.5 MHz, depending on the speed of the network to which the external PHY is attached. The RX_CLK is a continuous clock during the reception of the frame, but can be stopped for up to two RX_CLK periods at the beginning and the end of frames, so that the external PHY can sync up to the network data traffic necessary to recover the receive clock. During this time, the external PHY may switch to the TX_CLK to maintain a stable clock on the receive interface. The Am79C973/Am79C975 controller will handle this situa- tion with no loss of data. The data is a nibble-wide (4 bits) data path, RXD(3:0), from the external PHY to the Am79C973/Am79C975 controller and is synchronous to the rising edge of RX_CLK. The receive process starts when RX_DV is asserted. RX_DV will remain asserted until the end of the receive frame. The Am79C973/Am79C975 controller requires CRS (Carrier Sense) to toggle in between frames in order to receive them properly. Errors in the currently received frame are signaled across the MII by the RX_ER pin. RX_ER can be used to signal special con- ditions out of band when RX_DV is not asserted. Two defined out-of-band conditions for this are the 100BASE-TX signaling of bad Start of Frame Delimiter and the 100BASE-T4 indication of illegal code group before the receiver has synched to the incoming data. The Am79C973/Am79C975 controller will not respond to these conditions. All out of band conditions are cur- rently treated as NULL events. Certain in band non- IEEE 802.3u-compliant flow control sequences may cause erratic behavior for the Am79C973/Am79C975 controller. Consult the switch/bridge/router/hub manual to disable the in-band flow control sequences if they are being used. MII Network Status Interface The MII also provides signals that are consistent and necessary for IEEE 802.3 and IEEE 802.3u operation. These signals are CRS (Carrier Sense) and COL (Col- lision Sense). Carrier Sense is used to detect non-idle activity on the network. Collision Sense is used to indi- cate that simultaneous transmission has occurred in a half-duplex network. MII Management Interface The MII provides a two-wire management interface so that the Am79C973/Am79C975 controller can control and receive status from external PHY devices. The Am79C973/Am79C975 controller can support up to 31 external PHYs attached to the MII Management Interface with software support and only one such de- vice without software support. The Network Port Manager copies the PHYADD after the Am79C973/Am79C975 controller reads the EE- PROM and uses it to communicate with the external PHY. The PHY address must be programmed into the EEPROM prior to starting the Am79C973/Am79C975 controller. This is necessary so that the internal man- agement controller can work autonomously from the software driver and can always know where to access the external PHY. The Am79C973/Am79C975 control- ler is unique by offering direct hardware support of the external PHY device without software support. The PHY address of 1Fh is reserved and should not be used. To access the 31 external PHYs, the software driver must have knowledge of the external PHY’s ad- dress when multiple PHYs are present before attempt- ing to address it. The MII Management Interface uses the MII Control, Address, and Data registers (BCR32, 33, 34) to control a nd co mm un ica t e t o t he ex t e r n a l PHYs. T h e Am79C973/Am79C975 controller generates MII man- agement frames to the external PHY through the MDIO pin synchronous to the rising edge of the Management Data Clock (MDC) based on a combination of writes and reads to these registers. MII Management Frames MII management frames are automatically generated by the Am79C973/Am79C975 controller and conform to the MII clause in the IEEE 802.3u standard. The start of the frame is a preamble of 32 ones and guarantees that all of the external PHYs are synchro- nized on the same interface. See Figure C-78. Loss of synchronization is possible due to the hot-plugging ca- pability of the exposed MII. The IEEE 802.3 specification allows you to drop the preamble, if after reading the MII Status Register from the external PHY you can determine that the external PHY will support Preamble Suppression (BCR34, bit 6). After having a valid MII Status Register read, the Am79C973/Am79C975 controller will then drop the creation of the preamble stream until a reset occurs, re- ceives a read error, or the external PHY is discon- nected. |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |