| Datenblatt-Suchmaschine für elektronische Bauteile |
|
AM79C975VCW Datenblatt(PDF) 271 Page - Advanced Micro Devices |
|
|
|||||||||||||||||||||||||||||
AM79C975VCW Datenblatt(HTML) 271 Page - Advanced Micro Devices |
|
271 / 304 page ![]() Am79C973/Am79C975 271 P R E L I M INARY PHY by generating MII management frames. These frames will be sent roughly every 900 ms. These frames are necessary so that the Network Port Man- ager can monitor the current active link and can select a different network port if the current link goes down. Auto-Negotiation Through the external PHY, the following capabilities are possible: 100BASE-T4, 100BASE-TX Full-/Half-Du- plex, and 10BASE-T Full-/Half-Duplex. The capabilities are then sent to a link partner that will also send its ca- pabilities. Both sides look to see what is possible and then they will connect at the greatest possible speed and capability as defined in the IEEE 802.3u standard and according to Table C-68. By default, the link partner must be at least 10BASE-T half-duplex capable. The Am79C973/Am79C975 con- troller can automatically negotiate with the network and yield the highest performance possible without soft- ware support. See the section on Network Port Man- ager for more details. Auto-Negotiation goes further by providing a message- based communication scheme called, Next Pages, be- fore connecting to the Link Partner. This feature is not suppor ted in Am79C973/Am79C975 unless the DANAS (BCR32, bit 10) is selected and the software driver is capable of controlling the external PHY. A com- plete bit description of the MII and Auto-Negotiation registers can be found in the MII Management Regis- ters section. Automatic Network Port Selection If ASEL (BCR2, bit 0) is set to 1 and DANAS (BCR 32, bit 7) is set to 0, then the Network Port Manager will start to configure the external PHY if it detects the ex- ternal PHY on the MII Interface. Automatic Network Selection: Exceptions If ASEL (BCR2, bit 0) is set to 0 or DANAS (BCR 32, bit 7) is set to 1, then the Network Port Manager will dis- continue actively trying to establish the connections. It is assumed that the software driver is attempting to configure the network por t and the Am79C973/ Am79C975 controller will always defer to the software driver. When The ASEL is set to 0, the software driver should then configure the por ts with PORTSEL (CSR15, bits 7-8). Note: It is highly recommended that ASEL and PORTSEL be used when trying to manually configure a specific network port. In order to manually configure the External PHY, the recommended procedure is to force the PHY config- urations when Auto-Negotiation is not enabled. Set the DANAS bit (BCR32, bit 7) to turn off the Network Port Manager. Then clear the XPHYANE (BCR32, bit 5) and set either XPHYFD (BCR32, bit 4) or XPHYSP (BCR32, bit 3) or both. The Network Port Manager will send a few MII frames to the PHY to validate the con- figuration. CAUTION: The Network Port Manager utilizes the PHYADD (BCR33, bits 9-5) to communicate with the external PHY during the automatic port selection pro- cess. The PHYADD is copied into a shadow register after the Am79C973/Am79C975 controller has read the configuration information from the EEPROM. Ex- treme care must be exercised by the host software not to access BCR33 during this time. A read of PVALID (BCR19, bit 15) before accessing BCR33 will guaran- tee that the PHYADD has been shadowed. Am79C973/Am79C975’s Automatic Network Port se- lection mechanism falls within the following general categories: n External PHY Not Auto-Negotiable n External PHY Auto-Negotiable Automatic Network Selection: External PHY Not Auto-Negotiable This case occurs when the MIIPD (BCR32, bit 14) bit is 1. This indicates that there is an external PHY attached to Am79C973/Am79C975 controller’s MII. If more than one external PHY is attached to the MII Management Interface, then the DANAS (BCR32, bit 7) bit must be set to 1 and then all configuration control should revert to software. The Am79C973/Am79C975 controller will read the register of the external PHY to determine its status and network capabilities. See the MII Manage- ment Registers section for the bit descriptions of the MII Status register. If the external PHY is not Auto-Ne- gotiation capable and/or the XPHYANE (BCR32, bit 5) bit is set to 0, then the Network Port Manager will match up the external PHY capabilities with the XPHYFD (BCR 32, bit 4) and the XPHYSP (BCR32, bit 3) bits programmed from the EEPROM. The Am79C973/ Am79C975 controller will then program the external PHY with those values. A new read of the external PHYs MII Status register will be made to see if the link is up. If the link does not come up as programmed after a specific time, the Am79C973/Am79C975 controller will fail the external PHY link. The Network Port Man- Table 68. Auto-Negotiation Capabilities Network Speed Physical Network Type 200 Mbps 100BASE-X, Full Duplex 100 Mbps 100BASE-T4, Half Duplex 100 Mbps 100BASE-X, Half Duplex 20 Mbps 10BASE-T, Full Duplex 10 Mbps 10BASE-T, Half Duplex |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |